Intersection Line Length Normalization in CT Projection Data

نویسندگان

  • Jan Müller
  • Thorsten M. Buzug
چکیده

We present a method to improve the quality of common sinogram restoration algorithms, which are used for metal-artifact reduction in X-ray CT. The presented approach is based on the idea that the intersection length of all beams through the object of interest can approximately be calculated from a preliminary reconstruction of the object. Incorporating this information to the reconstruction allows significant reduction of streak artifacts. Additionally, it is shown that the information about intersection length may also be used to improve the detection of metal shadows within the sinogram.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Volume difference inequalities for the projection and intersection bodies

In this paper, we introduce a new concept of volumes difference function of the projection and intersection bodies. Following this, we establish the Minkowski and Brunn-Minkowski inequalities for volumes difference function of the projection and intersection bodies.

متن کامل

The application of X-ray beam hardening correction based on polynomial fitting in local scan

2 national X ray digital imaging center; Mianyang,China Abstract Beam Hardening effect would be induced due to broad energy spectrum of X-ray. Beam Hardening would lead to artifacts in CT reconstructed images, such as cupping artifact, streak artifact and metal artifact, so that the quality of CT image degrades. One efficient beam hardening correction method is building a mathematical law betwe...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Comparison of the rebuilding effects of different computed tomography scanners and reconstructive settings for the five-line sign in normal interlobular fissures

Background: Based on the images generated from two multi-slice computed tomography (CT) scanners, we intended to compare the five-line sign of normal interlobular fissures produced on axial or oblique maximum intensity projection (MIP) reconstructions using different algorithms. Methods: Two groups of 50 subjects underwent either 16-slice or 256-slice spiral unenhanced chest CT. None of them in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008