ROC Analysis for Evaluation of Radiation Biodosimetry Technologies.

نویسندگان

  • Benjamin B Williams
  • Ann Barry Flood
  • Eugene Demidenko
  • Harold M Swartz
چکیده

Receiver operating characteristic (ROC) analysis is a fundamental tool used for the evaluation and comparison of diagnostic systems that provides estimates of the combinations of sensitivity and specificity that can be achieved with a given technique. Along with critical considerations of practical limitations, such as throughput and time to availability of results, ROC analyses can be applied to provide meaningful assessments and comparisons of available biodosimetry methods. Accordingly, guidance from the Food and Drug Administration to evaluate biodosimetry devices recommends using ROC analysis. However, the existing literature for the numerous biodosimetry methods that have been developed to address the needs for triage either do not contain ROC analyses or present ROC analyses where the dose distributions of the study samples are not representative of the populations to be screened. The use of non-representative sample populations can result in a significant spectrum bias, where estimated performance metrics do not accurately characterize the true performance under real-world conditions. Particularly, in scenarios where a large group of people is screened because they were potentially exposed in a large-scale radiation event, directly measured population data do not exist. However, a number of complex simulations have been performed and reported in the literature that provide estimates of the required dose distributions. Based on these simulations and reported data about the output and uncertainties of biodosimetry assays, we illustrate how ROC curves can be generated that incorporate a realistic representative sample. A technique to generate ROC curves for biodosimetry data is presented along with representative ROC curves, summary statistics and discussion based on published data for triage-ready electron paramagnetic resonance in vivo tooth dosimetry, the dicentric chromosome assay and quantitative polymerase chain reaction assay. We argue that this methodology should be adopted generally to evaluate the performance of radiation biodosimetry screening assays so that they can be compared in the context of their intended use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective assessment of radiation dose by Fluorescence In Situ Hybridization and evaluation of stable chromosomal aberrations

Estimation of absorbed dose for radiation workers or person involved in different radiological accident is the aim of biodosimetry. Cytogenetic methods are the most current and applicable biodosimetry tools. In chronic or protracted exposure, fluorescence in situ hybridization (FISH), stable chromosomal aberration is used for estimation of absorbed dose. For precise estimation of absorbed dose,...

متن کامل

PHA stimulation may be useful for FDXR gene expression-based biodosimetry

Objective(s): Nowadays, ionizing radiation (IR) has a significant contribution to the diagnostic and therapeutic medicine, and following that, health risks to individuals through unexpected exposure is greatly increased. Therefore, biological and molecular technology for estimation of dose (biodosimetry) is taken into consideration. In biodosimetry methods stimulation ...

متن کامل

Induction of premature chromosome condensation (PCC) by calyculin A for biodosimetry

Background: Premature chromosome condensation (PCC) is a method for interphase chromosome analysis in biodosimetry. This study was performed to verify the usefulness of PCC induced by calyculin A in human peripheral blood lymphocytes (pbl) for biological dosimetry and possible construction of dose-response curve. Materials and Methods: Peripheral blood was obtained from a healthy donor and expo...

متن کامل

The RABiT: high-throughput technology for assessing global DSB repair.

At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have developed a rapid automated biodosimetry tool (RABiT); this is a completely automated, ultra-high-throughput robotically based biodosimetry workstation designed for use following a large-scale radiological event, to perform radiation biodosimetry measurements based on a fingerstick blood sample. High throughput...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 172 1-3  شماره 

صفحات  -

تاریخ انتشار 2016