Early implant failure. Prognostic capacity of Periotest: retrospective study of a large sample.

نویسندگان

  • Blas Noguerol
  • Ricardo Muñoz
  • Francisco Mesa
  • Juan de Dios Luna
  • Francisco O'Valle
چکیده

OBJECTIVES The objectives of this study were to determine the accuracy of Periotest to monitor primary implant stability at first-stage surgery, to identify by multivariate analysis the variables associated with early implant failure and to compare Periotest with radiographic study in the diagnosis of implant stability at second-stage surgery (during osseointegration period). MATERIAL AND METHODS A 10-year retrospective study was conducted on 1084 Brånemark implants placed in 316 patients. Clinical variables, implant diameter and length, Periotest values (PTVs) and radiological variables were analyzed in bivariate and multivariate studies in order to determine their influence on early implant failure. RESULTS After examination of the sensitivity and specificity values obtained for different PTV cutoff points, a cutoff PTV of -2 was selected (84% sensitivity and 39% specificity). In the bivariate analysis, early failure was significantly related to smoking habits, implant location, bone type, implant features and PTVs (-2 and >or=-2). In the final multiple logistic model, only age (odds ratio (OR)=4.53; 95% confidence interval (CI), 1.34-15.27), smoking habits (OR=2.5; 95% CI, 1.3-4.79), bone type (OR=1.93; 95% CI, 1.01-3.7) and PTV at first surgery (OR=3.01; 95% CI, 1.5-6.02) were independently related to early failure. CONCLUSIONS The Periotest (with -2 cutoff) at first surgery offers high sensitivity in the prognosis of early implant loss and shows a greater capacity to evaluate stability during the osseointegration period compared with radiographic study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study

Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...

متن کامل

Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study

Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...

متن کامل

Clinical efficacy of early loading versus conventional loading of dental implants

The aim of this study was to determine the clinical differences between early and conventional loading protocols for dental implants. A comprehensive search of the Medline, Embase, and OVID databases for studies published through January 10, 2015 was conducted. Fourteen studies were included in our analysis. We found that early loading imposed a significantly higher risk of implant failure than...

متن کامل

Narrow-diameter implants with conical connection for restoring the posterior edentulous region

BACKGROUND The objective of this retrospective study was to show results from platform-switched narrow-diameter implants in the posterior edentulous region, which we followed up for more than 1 year after functional loading. METHODS Ninety-eight narrow implants were inserted into 66 patients. After healing, fixed implant-supported prostheses were delivered to the patients, and Periotest and r...

متن کامل

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2006