Robust megavoltage x-ray spectra estimation from transmission measurements.

نویسندگان

  • Marian Manciu
  • Felicia S Manciu
  • Teodor Vulcan
  • Elena Nes
  • Robert G Waggener
چکیده

Megavoltage X-ray sources are commonly used for therapy planning, and knowledge of their spectral distribution is important for accurate dose calculations. There are many methods that could provide reasonable estimations of Megavoltage X-ray spectra, when very accurate attenuation data or at least very good set of initial guesses of the spectra are available. We present here a novel method, which can be used for accurate Megavoltage spectral reconstruction without any prior knowledge of spectral distribution; the method performs well even when the available transmission data are affected by noise. The method is based on a search for a smooth function that minimizes the differences between measured and calculated attenuation data. The algorithm is compared with well-known existing algorithms, using computer simulated data, both error-free and containing added random Gaussian noise. The reconstructed spectra are subsequently used to calculate the transmission through 50 cm of bone, muscle or fat tissue. It is shown that the relative errors in dose calculations, using the spectra reconstructed via this method, are significantly smaller than those obtained via well-established reconstruction algorithms--Truncated Singular Value Decomposition (TSVD) and Expectation Maximization (EM). These results suggest that the novel algorithm might be practical for routine Megavoltage therapy X-ray source calibration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An indirect transmission measurement-based spectrum estimation method for computed tomography.

The characteristics of an x-ray spectrum can greatly influence imaging and related tasks. In practice, due to the pile-up effect of the detector, it's difficult to directly measure the spectrum of a CT scanner using an energy resolved detector. An alternative solution is to estimate the spectrum using transmission measurements with a step phantom or another CT phantom. In this work, we present ...

متن کامل

An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements.

PURPOSE Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors...

متن کامل

Facile Synthesis and Spectroscopic Studies of SiO2-Core/ZnS-Shell Nanostructure

SiO2/ZnS core/shell nanostructures have been synthesized at room temperature by a simple wet chemical method. The prepared materials are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), infrared spectroscopy (IR), UV–vis spectroscopic and transmission electron microscopy (TEM) studies. X-ray diffraction pattern exhibits peaks correspond to the cubic phase of ZnS. Th...

متن کامل

Radiosensitization effect of ZnO nanoparticles in lung cancer cells at clinically relevant megavoltage energy

Introduction: Radiation therapy is one of the major modalities that have long been used in cancer treatment. Radiotherapy is often accompanied by early and late toxicity and side effects and narrow therapeutic window. Similarity in radiation absorption properties of tumors and neighboring healthy tissues is often the reason for low specificity of radiation therapy. Development ...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of X-ray science and technology

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2009