Alternative input devices for efficient navigation of large CT angiography data sets.

نویسندگان

  • Anthony J Sherbondy
  • Djamila Holmlund
  • Geoffrey D Rubin
  • Pamela K Schraedley
  • Terry Winograd
  • Sandy Napel
چکیده

PURPOSE To compare devices for the task of navigating through large computed tomographic (CT) data sets at a picture archiving and communication system workstation. MATERIALS AND METHODS The institutional review board approved this study, and all subjects provided informed consent. Five radiologists were asked to find 25 different vascular targets in three CT angiography data sets (average number of sections, 1025) by using several devices (trackball, tablet, jog-shuttle wheel, and mouse). For each trial, the total time to acquire the targets (T1) was recorded. A secondary study in which 13 nonradiologists performed seven trials with an artificial target inserted at a random location in the same image data was also performed. For each trial, the following items were recorded: time until first target sighting (t2), time to manipulate the device after seeing the target, sections traversed during t2 (d1), time from first sight to target acquisition (t4), sections traversed during t4 (d2), and total trial time. Statistical analysis involved repeated-measures analysis of variance (ANOVA) and pairwise comparisons. RESULTS Repeated-measures ANOVA revealed that the device used had a significant (P < .05) effect on T1. Pairwise comparisons revealed that the trackball was significantly slower than the tablet (P < .05) and marginally slower than the jog-shuttle wheel (P < .10). Further repeated-measures ANOVA for each secondary outcome measure revealed significant differences between devices for all outcome measures (P < .005). Pairwise comparisons revealed the trackball to be significantly slower than the other devices in all measures (P < .05). The trackball was significantly (P < .05) more accurate than the other devices for d1 and d2. CONCLUSION The trackball may not be the optimal device for navigation of large CT angiography data sets; the use of other existing devices may improve the efficiency of interpretation of these sets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

توزیع تجهیزات پزشکی تشخیصی درمانی سرمایه‌ای در ایران در سال 1395 و برآورد تعداد دستگاه مورد نیاز تا سال 1404

Background and Objectives: Iran is a large country that is often an importer of major medical equipment. There is no comprehensive databank of the status of the equipment in the country. The present study provides a clear description of the dispersal status of major medical equipment in the country in 2016 and the estimated number of required devices in 2026.   Methods: This study was conduct...

متن کامل

Transradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note

Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...

متن کامل

Applications of Inertial Navigation Systems in Medical Engineering

Inertial navigation systems are of the most important and practical systems in determining the velocity, position and attitude of the vehicles and different equipment. In these systems, three accelerometers and three gyroscopes are used to measure linear accelerations and angular velocities of vehicles, respectively. By using the output of these sensors and special inertial algorithms in differ...

متن کامل

ALTERNATIVE MIXED INTEGER PROGRAMMING FOR FINDING EFFICIENT BCC UNIT

Data Envelopment Analysis (DEA) cannot provide adequate discrimination among efficient decision making units (DMUs). To discriminate these efficient DMUs is an interesting research subject. The purpose of this paper is to develop the mix integer linear model which was proposed by Foroughi (Foroughi A.A. A new mixed integer linear model for selecting the best decision making units in data envelo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 234 2  شماره 

صفحات  -

تاریخ انتشار 2005