An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates

نویسندگان

  • R. Garrett Jeffries
  • Laura Lund
  • Brian Frankowski
  • William J. Federspiel
چکیده

BACKGROUND Extracorporeal carbon dioxide removal (ECCO2R) systems have gained clinical appeal as supplemental therapy in the treatment of acute and chronic respiratory injuries with low tidal volume or non-invasive ventilation. We have developed an ultra-low-flow ECCO2R device (ULFED) capable of operating at blood flows comparable to renal hemodialysis (250 mL/min). Comparable operating conditions allow use of minimally invasive dialysis cannulation strategies with potential for direct integration to existing dialysis circuitry. METHODS A carbon dioxide (CO2) removal device was fabricated with rotating impellers inside an annular hollow fiber membrane bundle to disrupt blood flow patterns and enhance gas exchange. In vitro gas exchange and hemolysis testing was conducted at hemodialysis blood flows (250 mL/min). RESULTS In vitro carbon dioxide removal rates up to 75 mL/min were achieved in blood at normocapnia (pCO2 = 45 mmHg). In vitro hemolysis (including cannula and blood pump) was comparable to a Medtronic Minimax oxygenator control loop using a time-of-therapy normalized index of hemolysis (0.19 ± 0.04 g/100 min versus 0.12 ± 0.01 g/100 min, p = 0.169). CONCLUSIONS In vitro performance suggests a new ultra-low-flow extracorporeal CO2 removal device could be utilized for safe and effective CO2 removal at hemodialysis flow rates using simplified and minimally invasive connection strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-Flow Extracorporeal Carbon Dioxide Removal Using the Hemolung Respiratory Dialysis System® to Facilitate Lung-Protective Mechanical Ventilation in Acute Respiratory Distress Syndrome.

Extracorporeal carbon dioxide removal (ECCO2R) permits reductions in alveolar ventilation requirements that the lungs would otherwise have to provide. This concept was applied to a case of hypercapnia refractory to high-level invasive mechanical ventilator support. We present a case of an 18-year-old man who developed post-pneumonectomy acute respiratory distress syndrome (ARDS) after resection...

متن کامل

Extracorporeal CO2 removal by hemodialysis: in vitro model and feasibility

BACKGROUND Critically ill patients with acute respiratory distress syndrome and acute exacerbations of chronic obstructive pulmonary disease often develop hypercapnia and require mechanical ventilation. Extracorporeal carbon dioxide removal can manage hypercarbia by removing carbon dioxide directly from the bloodstream. Respiratory hemodialysis uses traditional hemodialysis to remove CO2 from t...

متن کامل

Femoral arteriovenous extracorporeal carbon dioxide elimination using low blood flow.

BACKGROUND AND METHODS Conventional extracorporeal CO2 removal systems require blood flow rates of 1 to 2.5 L/min in the extracorporeal circuit. We hypothesized that standard hemofiltration equipment can be combined with a high-performance extracorporeal lung to achieve high rates of CO2 removal at lower blood flow rates. To test this hypothesis, we performed experiments on nine sheep to examin...

متن کامل

Size of Cannulae for Extracorporeal Co2 Removal Therapies

Extracorporeal CO2 removal devices (ECCO2R) can be used in clinics to decarboxylate blood externally for patients suffering from pulmonary insufficiencies like acute respiratory distress syndrome. In this work, we propose a model of the respiratory system coupled with such a device to analyze the decrease of CO2 partial pressure in the blood as a function of the blood flow through the device. T...

متن کامل

A Retrospective Observational Case Series of Low-Flow Venovenous Extracorporeal Carbon Dioxide Removal Use in Patients with Respiratory Failure.

We aimed to describe the use of venovenous extracorporeal carbon dioxide removal (ECCO2R) in patients with hypercapnic respiratory failure. We performed a retrospective case note review of patients admitted to our tertiary regional intensive care unit and commenced on ECCO2R from August 2013 to February 2015. Fourteen patients received ECCO2R. Demographic data, physiologic data (including pH an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017