Accurate calibration and control of relative humidity close to 100% by X-raying a DOPC multilayer.

نویسندگان

  • Yicong Ma
  • Sajal K Ghosh
  • Sambhunath Bera
  • Zhang Jiang
  • Stephanie Tristram-Nagle
  • Laurence B Lurio
  • Sunil K Sinha
چکیده

In this study, we have designed a compact sample chamber that can achieve accurate and continuous control of the relative humidity (RH) in the vicinity of 100%. A 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) multilayer can be used as a humidity sensor by measuring its inter-layer repeat distance (d-spacing) via X-ray diffraction. We convert from DOPC d-spacing to RH according to a theory given in the literature and previously measured data of DOPC multilamellar vesicles in polyvinylpyrrolidone (PVP) solutions. This curve can be used for calibration of RH close to 100%, a regime where conventional sensors do not have sufficient accuracy. We demonstrate that this control method can provide RH accuracies of 0.1 to 0.01%, which is a factor of 10-100 improvement compared to existing methods of humidity control. Our method provides fine tuning capability of RH continuously for a single sample, whereas the PVP solution method requires new samples to be made for each PVP concentration. The use of this cell also potentially removes the need for an X-ray or neutron beam to pass through bulk water if one wishes to work close to biologically relevant conditions of nearly 100% RH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of daily evaporation using hybrid support vector regression-firefly optimization algorithm and multilayer perceptron

Prediction of daily evaporation is a valuable and determinant tool in sustainable agriculture and hydrological issues, especially in the design and management of water resources systems. Therefore, in this study, the ability of artificial intelligence models of multi-layer perceptron (MLP), support vector regression (SVR), and the hybrid model of support vector regression-firefly optimization a...

متن کامل

Pattern Changes Analysis Of Soil Temperature In Different Depths Under The Influence Of Humidity And Air Temperature (Case Study: Taleghan Watershed)

In this study, to analyze the pattern of soil temperature changes in the depths of  5, 10, 20, 30, 50 and 100 cm under the influence of temperature (minimum, average and maximum) and humidity (minimum, average and maximum) the Pearson and regression methods were used for Taleghaan synoptic station during the period of 2008 to 2016 . The results showed that soil temperature had the highest corre...

متن کامل

Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range

 ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...

متن کامل

Diversity assessment and the effect of temperature and humidity on the relative abundance of medically important fly species in Fouladshahr, Isfahan, 2019

Introduction: Flies are able to mechanically transmit many pathogenic agents due to their close relationship with humans. Identification and species determination of flies for understanding of their current status and planning for their control, as well as considering the important role of flies in the ecosystem and their biological functions in biological studies, is essential. The purpose of ...

متن کامل

The Effect of Percentage of Remaining Hair Bred and Ambient Relative Humidity on Electrical Resistance of Cashmere Fiber

Among different types of controlling systems, the ON/OFF digital relative humidity control was used for measuring electrical properties of cashmere fibers to make the ambient relative humidity fixed. To achieve this goal the required hardware and software were designed and fabricated. The electrical resistance of fine and coarse hair cashmere fiber was measured by charge and discharge condenser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 17 5  شماره 

صفحات  -

تاریخ انتشار 2015