Anti-slug control solutions based on identified model

نویسندگان

  • Esmaeil Jahanshahi
  • Sigurd Skogestad
چکیده

A anti-slug control requires operation around an open-loop unstable operating point. One solution is to design a robust controller based on a mechanistic model. An alternative and more robust approach is to identify an unstable model of the system based on input-output data. We used a closed-loop step test to identify an unstable linear model. From this, we obtained a second order IMC (Internal Model Control) controller that can be implemented as a PIDF controller. From the asymptotes of the proposed IMC controller, we also derive a simple tuning for PI-controller. Next, we considered two types of robust H∞ controller (mixed-sensitivity and loop-shaping). The proposed model identification and control solutions were verified experimentally on two different test rigs. We found that the robustness and performance of the IMC (PIDF) controller is comparable with the H∞ controllers. However, the prosed IMC (PIDF) controller is easier to tune compared to H∞ control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Model-Based Control Solutions for Severe Riser-Induced Slugs

Control solutions for eliminating severe riser-induced slugs in offshore oil & gas pipeline installations are key topics in offshore Exploration and Production (E&P) processes. This study describes the identification, analysis and control of a low-dimensional control-oriented model of a lab-scaled slug testing facility. The model is analyzed and used for anti-slug control development for both l...

متن کامل

Review of Slug Detection, Modeling and Control Techniques for Offshore Oil & Gas Production Processes

The current offshore oil & gas multi-phase production and transportation installations have big challenges related with the slugging flow: An unstable multi-phase flow regime where the flow rates, pressures and temperatures oscillate in the considered processes. Slug can be caused by different operating conditions and installation structures. The most severe slugs are often induced in long vert...

متن کامل

Cascade Control Experiments of Riser Slug Flow Using Topside Measurements

Anti-slug control applied to two-phase flow provides a very challenging and important application for feedback control. It is important because it allows for operation that would otherwise be impossible, and challenging because of the presence of both RHP-poles and RHP-zeros. To conduct experiments on pipeline-riser anti-slug control, a small-scale slug-loop has been build. The loop has been mo...

متن کامل

Anti-slug control experiments on a small-scale two-phase loop

Anti-slug control applied to two-phase flow provides a very challenging and important application for feedback control. It is important because it allows for operation that would otherwise be impossible, and challenging because of the presence of both RHP-poles and RHP-zeros. To conduct experiments on pipeline-riser anti-slug control, a small-scale slug-loop has been build. The loop has been mo...

متن کامل

Modeling of A Single Turn Pulsating Heat Pipe based on Flow Boiling and Condensation Phenomena

Demand for high-performance cooling systems is one of the most challenging and virtual issues in the industry and Pulsating heat pipes are effective solutions for this concern. In the present study, the best predictor correlations of flow boiling and condensation are taken into account to model a single turn pulsating heat pipe mathematically. These considerations, result in derivation of more ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014