Compression clamp for use in fractures of the tibia.

نویسنده

  • J D Hamer
چکیده

~~~~~~~~~~~~~~~~~~~~W Mr. N. SHAH, lecturer, Professorial Unit, the Institute of Laryngology and Otology, London W.C.1, writes: Myringotomy and aspiration of fluid from the middle ear is a common practice in otology. Children with fluid (serous or "glue ") are operated on under general anaesthesia with the aid of a Zeiss microscope. A glass suction cannula (see photograph) for aspiration of fluid from the middle ear can be made to any desired angle in the laboratory from a Pasteur pipette. A hole to control the suction is made on the side of the stem by blowing through the pipette when it is hot. The material can be seen through the transparent end of the pipette, and can readily be transferred into a suitable container by expelling with a disposable sterile syringe connected to the pipette by means of a piece of rubber tubing with a Luer adapter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...

متن کامل

Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia

Background:  Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

متن کامل

Assessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating

  Abstract   Background: The tibial diaphyseal fractures are the most common type of long   bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia   fractures have the second incidence of all tibia fractures after the middle tibia fractures.   The purpose of the study was to asses...

متن کامل

Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...

متن کامل

Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques

Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model.A split fracture of the lateral tibia plateau (AO/OTA type 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 1 5642  شماره 

صفحات  -

تاریخ انتشار 1969