Automatic Sampling and Analysis of Organics and Biomolecules by Capillary Action-Supported Contactless Atmospheric Pressure Ionization Mass Spectrometry

نویسندگان

  • Cheng-Huan Hsieh
  • Anil Kumar Meher
  • Yu-Chie Chen
چکیده

Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary action-supported contactless atmospheric pressure ionization for the combined sampling and mass spectrometric analysis of biomolecules.

It is proposed that a short tapered capillary can be utilized as a nanoliter-volume sampling tool and sample emitter for generation of gas-phase ions in front of the mass spectrometer, without the need for using an additional electric power supply, a gas supply, or a syringe pump. A wide range of molecules can be analyzed in pure solutions and complex matrixes (cell extract, urine, and plant ti...

متن کامل

Online monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometry.

Online monitoring of the appearance of the intermediates and products during chemical reactions is helpful to understand reaction mechanisms. Various analytical tools including nuclear magnetic resonance spectroscopy, Raman spectroscopy and mass spectrometry (MS) have been employed for the study. MS is one of the most promising means among analytical tools that can provide information of mass-t...

متن کامل

Simultaneous imaging of small metabolites and lipids in rat brain tissues at atmospheric pressure by laser ablation electrospray ionization mass spectrometry.

Atmospheric pressure imaging mass spectrometry is a rapidly expanding field that offers advantages in the ability to study biological systems in their native condition, simplified sample preparation, and high-throughput experiments. In laser ablation electrospray ionization (LAESI), the native water molecules in biological tissues facilitate sampling by a focused mid-infrared laser beam. The io...

متن کامل

Droplet-based electrospray ionization mass spectrometry for qualitative and quantitative analysis.

Mass spectrometry (MS) is a rapid and sensitive analytical tool that can provide information such as molecular weight and structure. One of the fast growing fields in MS in the beginning of this century is the development of ion sources at atmospheric pressure. Speed, simplicity and minimal sample preparation are the main characteristics of these recently developed ion sources at open air. Most...

متن کامل

Analysis of Polymer Additives and Impurities by Liquid Chromatography/Mass Spectrometry and Capillary Electrophoresis/Mass Spectrometry

The analysis of polymeric materials can be quite challenging because such samples are often of complex nature due to the presence of various groups of additives, compounding ingredients, and fillers. Of special importance are stabilizers that protect the material from degradation by thermal stress during manufacture or from environmental impact during use. Apart from intact stabilizers, the deg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013