Alternative antibody for the detection of CA19-9 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access GI Monitor assay on the UniCel DxI 800 Immunoassay System

نویسندگان

  • Petra Stieber
  • Rafael Molina
  • Massimo Gion
  • Axel Gressner
  • Frédéric Troalen
  • Stefan Holdenrieder
  • Jose Maria Auge
  • Matelda Zancan
  • Matthias Wycislo
  • Véronique Jarrige
چکیده

Background: Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer. Methods: The analytical and clinical performance of the Access GI Monitor assay (Beckman Coulter) was evaluated on the UniCel DxI 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SDq7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries: hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access GI Monitor and Elecsys CA19-9 (Rs0.959, slopes1.004, interceptsq0.17). GI Monitor serum levels were low in healthy individuals (ns267, medians6.0 kU/L, 95th percentiles23.1 kU/L), higher *Corresponding author: Dr. med. Petra Stieber, Institut für Klinische Chemie, Klinikum der Universität München, Marchioninistr. 15, 81366 Munich, Germany Phone: q49-89-7095-3115, Fax: q49-89-7095-6298, E-mail: [email protected] Received July 19, 2007; accepted October 4, 2007 in individuals with various benign diseases (ns550, medianss5.8–13.4 kU/L, 95th percentiless30.1–195.5 kU/L) and even higher in individuals suffering from various cancers (ns995, medianss8.4–233.8 kU/L, 95th percentiless53.7–13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer warea under the curve (AUC) 0.83x. Results for the reference CA19-9 assay were comparable (AUC 0.85). Conclusions: The Access GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers. Clin Chem Lab Med 2008;46:600–11.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alternative antibody for the detection of CA125 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access OV Monitor assay on the UniCel DxI 800 Immunoassay System

Background: Cancer antigen CA125 is known as a valuable marker for the management of ovarian cancer. Methods: The analytical and clinical performance of the Access OV Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA125 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the ...

متن کامل

Alternative antibody for the detection of CA15-3 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access BR Monitor assay on the UniCel DxI 800 Immunoassay System

Background: Cancer antigen CA15-3 antigen is known as a valuable marker for the management of breast cancer. Methods: The analytical and clinical performance of the Access BR Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA15-3 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV...

متن کامل

Evaluation of the UniCel™ DxI 800 Immunoassay Analyzer in Measuring Five Tumor Markers

PURPOSE Tumor marker concentrations in a given specimen measured by different analyzers vary according to assay methods, epitopes for antibodies used, and reagent specificities. Although great effort in quality assessment has been instituted, discrepancies among results from different analyzers are still present. We evaluated the assay performance of the UniCel™ DxI 800 automated analyzer in me...

متن کامل

Clinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection.

Various automated chemiluminescence immunoassay (CLIA) analyzers for the detection of antibodies to hepatitis C virus (HCV) are now commercially available in clinical laboratories and are replacing conventional enzyme immunoassays. We investigated the performance of four anti-HCV CLIAs (the Architect Anti-HCV assay on the Architect i2000 system, the Vitros Anti-HCV assay on the Vitros ECiQ Immu...

متن کامل

Performance characteristics of the UniCel DxI 800 immunoassay for the maternal serum quadruple test, including median values for each week of gestation, in Korean women.

BACKGROUND Maternal serum prenatal quadruple screening includes testing for alpha-fetoprotein (AFP), human chorionic gonadotrophin (hCG), unconjugated estriol (uE3), and dimeric inhibin A (DIA). We evaluated quadruple screening using an automated platform and looked for any ethnic differences in the median values of each marker. METHODS We measured the concentrations of each quadruple test an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008