Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

نویسندگان

  • J L Tan
  • L F Hsu
  • R M L Kam
  • W S Teo
چکیده

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. OBJECTIVE To review the use, safety and efficacy of VDD pacing in a single tertiary referral centre. MATERIALS AND METHODS A review of all patients with atrioventricular block and normal sinus node function implanted with a VDD pacemaker over a 2-year period at a local tertiary cardiac referral centre. Data on complications, atrial sensing performance and maintenance of atrioventricular synchrony during implant and at subsequent follow-up visits were obtained from a prospectively maintained registry and analysed. RESULTS Forty-one patients (17 males, 24 females) with a mean age of 72 +/- 9 years received VDD pacing for various forms of high-grade atrioventricular block. The average implantation time was 46.8 +/- 17.1 minutes, and a pneumothorax in 1 patient was the only complication. Electrical measurements at implantation and subsequent follow-up visits revealed an initial rapid decrease in atrial signal amplitude (mean atrial P wave at implant 3.1 +/- 1.1 mV, predischarge 1.9 +/- 1.3 mV) which began to stabilise after 3 months, reaching a mean atrial P wave value of 1.3 +/- 0.3 mV at 24 months. The atrial sensing performance (percentage of atrial synchronous ventricular complexes) was 97% over a mean follow-up period of 9.9 months. Four patients (10%) developed paroxysmal atrial tachyarrhythmias. Sinus node dysfunction was not observed in any of our patients during the follow-up period. CONCLUSION In patients with atrioventricular block and preserved sinus node function, single lead VDD pacing is safe and effective in maintaining a physiological atrial synchronous pacing mode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stable Atrial Sensing on Long-Term Follow Up of VDD Pacemakers

BACKGROUND The hemodynamic advantages of maintaining AV synchrony through AV synchronous pacing are widely known as compared to single chamber pacing. DDD pacemaker implantation entails higher cost and is technically more challenging than the VDD pacemaker. METHODS Seventy one patients underwent VDD lead (Biotronik GmbH, St. Jude Medical and Medtronic Inc.) implantation at KEM hospital, Mumba...

متن کامل

Sinus node function in children with congenital complete atrioventricular block.

AIMS Children with congenital complete atrioventricular block (CCAVB) often need pacemaker therapy. In these children, it may be preferable to use single-lead VDD pacing, but for VDD pacing a normal sinus node function is required. Our aim was to study sinus node function in children with CCAVB. METHODS AND RESULTS We longitudinally evaluated sinus rate in 36 children with CCAVB and normal an...

متن کامل

Predictors of loss of atrioventricular synchrony in single lead VDD pacing.

OBJECTIVE To evaluate maintenance of proper VDD function, defined as persistence of sinus rhythm with atrial synchronous ventricular pacing, and to define factors predicting failure of the VDD mode in patients with atrioventricular (AV) block and normal sinus function. DESIGN Observational study in 86 consecutive patients (mean (SD) age 74 (12) years; 38 women, 48 men) with single lead VDD pa...

متن کامل

[Safety and effectiveness of single-lead VDD pacing].

INTRODUCTION AND OBJECTIVES Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. METHOD In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symp...

متن کامل

Cost-effectiveness of dual-chamber pacemaker therapy: does single lead VDD pacing reduce treatment costs of atrioventricular block?

AIMS Implantation of single-lead VDD pacemakers is an established alternative to DDD pacing in patients with atrioventricular block. This study compares the long-term costs of both systems. METHODS AND RESULTS Three hundred and sixty patients with atrioventricular block received VDD or DDD pacemakers in alternating order. Primary costs of implantation included: devices, leads and operation ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2003