Noninvasive measurements and analysis of blood velocity profiles in human retinal vessels.

نویسندگان

  • Zhangyi Zhong
  • Hongxin Song
  • Toco Yuen Ping Chui
  • Benno L Petrig
  • Stephen A Burns
چکیده

PURPOSE To quantitatively model the changes in blood velocity profiles for different cardiac phases in human retinal vessels. METHODS An adaptive optics scanning laser ophthalmoscope (AOSLO) was used to measure blood velocity profiles in three healthy subjects. Blood velocity was measured by tracking erythrocytes moving across a scanning line. From the radial position of the cells within the lumen, the blood velocity profile was computed. The cardiac pulsatility was recorded with a cardiac signal monitor. RESULTS The shape of the blood velocity profile in retinal arteries changed systematically during the cardiac cycle, with the flattest profile occurring during the diastolic phase. The measured blood velocity profiles were typically flatter than the commonly assumed parabolic shape. The flatness increased with decreasing vessel size. For the large veins (>80 μm), the ratio of the centerline velocity to the cross-sectional average velocity was between 1.50 and 1.65. This ratio decreased to 1.36 in the smallest vein studied (32 μm). Velocity profiles downstream from a venous confluence showed two peaks at 120 μm from the confluence, but a single velocity peak 500 μm downstream from the confluence. CONCLUSIONS The cardiac cycle influences the blood flow velocity profiles systematically in retinal arteries but not in veins. Parabolic flow was not found in even the largest vessels studied, and deviations from parabolic flow increased in smaller vessels. The measurements are sensitive enough to measure the dual-humped blood velocity profile at a vein confluence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PERFORMANCE MODEL AND ANALYSIS OF BLOOD FLOW IN SMALL VESSELS WITH MAGNETIC EFFECTS

In this paper consider a two-fluid model consisting of a core region of suspension of all the erythrocytes (particles) in plasma (fluid) assumed to be a particle-fluid mixture and a peripheral layer of cell-free plasma (Newtonian fluid), has been proposed to represent blood flow in small diameter tubes with effects of magnetic. The analytical results obtained in the proposed model for effective...

متن کامل

A Mathematical Model for Blood Flow Through Narrow Vessels with Mild-Stenosis (RESEARCH NOTE)

In this paper we examine the effect of mild stenosis on blood flow, in an irregular axisymmetric artery with oscillating pressure gradient. The Herschel-Bulkley fluid model has been utilized for this study. The combined influence of an asymmetric shape and surface irregularities of constriction has been explored in this computational study. An extensive quantitative analysis has been performed ...

متن کامل

Measurement of Retinal Blood Flow Using Fluorescently Labeled Red Blood Cells1,2,3

Blood flow is a useful indicator of the metabolic state of the retina. However, accurate measurement of retinal blood flow is difficult to achieve in practice. Most existing optical techniques used for measuring blood flow require complex assumptions and calculations. We describe here a simple and direct method for calculating absolute blood flow in vessels of all sizes in the rat retina. The m...

متن کامل

Measurement of Retinal Blood Flow Using Fluorescently Labeled Red Blood Cells.

Blood flow is a useful indicator of the metabolic state of the retina. However, accurate measurement of retinal blood flow is difficult to achieve in practice. Most existing optical techniques used for measuring blood flow require complex assumptions and calculations. We describe here a simple and direct method for calculating absolute blood flow in vessels of all sizes in the rat retina. The m...

متن کامل

Toward noninvasive measurement of blood hematocrit using spectral domain low coherence interferometry and retinal tracking.

We demonstrate in vivo measurements in human retinal vessels of an experimental parameter, the slope of the low coherence interferometry (LCI) depth reflectivity profile, which strongly correlates with the real value of blood hematocrit. A novel instrument that combines two technologies, spectral domain low coherence interferometry (SDLCI) and retinal tracking, has been developed and used for t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 7  شماره 

صفحات  -

تاریخ انتشار 2011