Accurate heterogeneous dose calculation for lung cancer patients without high‐resolution CT densities

نویسندگان

  • Anneyuko I. Saito
  • Jonathan G. Li
  • Chihray Liu
  • Kenneth R. Olivier
  • James F. Dempsey
چکیده

The aim of this study was to investigate the relative accuracy of megavoltage photon-beam dose calculations employing either 5 bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full-resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with an adaptive convolution dose calculation algorithm (Pinnacle3, Philips Medicals Systems). Bulk densities were applied to segmented regions. Individual and population average densities were compared to the full-resolution plan for each case. Monitor units were kept constant and no normalizations were employed. Dose volume histograms (DVH) and dose difference distributions were examined for all cases. The average densities of the segmented air, lung, fat, soft tissue, and bone for the entire set were found to be 0.14, 0.26, 0.89, 1.02, and 1.12 g/cc, respectively. In all cases, the normal tissue DVH agreed to better than 2% in dose. In 62 of 70 target DVHs, agreement to better than 3% in dose was observed. Six cases demonstrated emphysema, one with bullous formations and one with a hiatus hernia having a large volume of gas. They required the additional assignment of density to the emphysemic lung and inflammatory changes to the lung, the regions of collapsed lung, the bullous formations, and the hernia gas. Bulk tissue density dose calculation provides an accurate method of heterogeneous dose calculation. However, patients with advanced emphysema may require high-resolution CT studies for accurate treatment planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Study of Tissue Heterogeneity Correction for Breast Conformal Radiotherapy

Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...

متن کامل

Comparison and Evaluation of the Effects of Rib and Lung Inhomogeneities on Lung Dose in Breast Brachytherapy using a Treatment Planning System and the MCNPX Code

Introduction: This study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (TPS) for 192Ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. Materials and Methods: A CT scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...

متن کامل

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...

متن کامل

Evaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation

Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...

متن کامل

The effect of CT contrast agents on treatment planning and dose calculation in radiation therapy of pelvis cancers

Introduction: Using contrast medium in diagnosis and identifying of an organ from its surrounding tissue is very useful. These contrast mediums alter radiation absorption of studied organs. The aim of this study is to identify the influences of contrast media in treatment planning system of the pelvis.   Materials and Methods: Seven patients with pelvis area ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009