Invalidation of clinistix tests.
نویسنده
چکیده
Clinistix is generally coiisidered to be specific for detection aiid rough quanti-tation of glucose in urine. The first reaction, being enzymatic. ittay be assumed to be specific. The second reaction-normally, oxidation of the chromogen by the product of enzyme action on glucose-may also be produced directly by hypo-chlorite (1), fumes of nitric acid (2), or other oxidizing agents acting on the chromogen. thus concealing a negative reaction or exaggerating a positive result. On the other hand, reducing substalices such as a large excess of ascorbic acid in urine resulting from excessive intake (3) or other reductants. possibly may modify the results downward (1). A urine specimen collected at home from a diabetic patient 6 hr. after his taking insulin and eating was believed to show a positive test which was inconsistent with previous findings. Upon investigation, a bottle of Polident denture cleaner was found on a shelf above the urinal, with a considerable amount of powder on the outside of the bottle. A pinch of Polident was dissolved in a cup of water and tested with a strip of Clinistix. Instantly there appeared the darkest color on the chart accompanying the strips. The contents of the cup was poured out and the filni remaining on the sides was again diluted to a full cup. When a fresh strip of Clinistix was dipped into this, the maximum color once again appeared immediately. This second dilution probably represented much less than 1 part in 100,000. Probably effervescent denture cleaners with the same formulation as Polident would show the same falsely positive reaction. Oxydol. a laundry product, gave a falsely positive result with about 1 gm. in a cup of water (8 oz.), but was negative on second dilution. Approximately 0.1 teaspoonful of Clorox (5.25% sodium hypochiorite) per cup of water gave similar results. Any household cleaner containing an oxidizing agent, such as scouring powders containing " stain removers, " may exhibit a similar reaction (4). Before leaving a hospital, doctor's office, or pharmacy with Clinistix to be used at home, the patient should be warned about these possible sources of arti-factual falsely low and high values. Personnel in clinical laboratories should also always be aware of such false reactions to a supposed specific test for glucose. and diagnostic specificity of laboratory tests. Levels of ascorbic acid in the blood plasma of apparently healthy children.
منابع مشابه
A laboratory trial of some modern screening tests for the detection of glucose and protein in urine.
In recent years a number of simple diagnostic tests on urine have been developed which are less time consuming than the procedures previously used. The most important are those for the detection of protein and glucose which will be considered here. The Ames Company has produced "albustix" and "clinistix" for the testing of urine for protein and glucose respectively. "Albustix" are strips of thi...
متن کاملOn invalidation mechanisms for non-robust delay tests
In most of the delay fault testing literature there is a widespread belief that a non-robust test for a path delay fault can be invalidated only through the existence of another path delay fault. In this paper we present an analysis of conditions that can invalidate a non-robust test, and present four di erent invalidation mechanisms. Three of these mechanisms, in addition to the pulse dampenin...
متن کاملEffective Approximate Fault Diagnosis of Systems with Inhomogeneous Test Invalidation
failed components in the system. In large multiprocessors a circuit-level fault diagnosis is impractical, therefore system-level diagnosis considers only processor faults. Processors periodically execute tests on each other. If an error was detected, the diagnostic procedure identifies faulty units by analyzing the collection of the test results (called the syndrome). Once these units were iden...
متن کاملTear glucose in diabetics.
THE purpose of this investigation was to evaluate a method of screening suspected diabetics, suitable for those without hospital facilities. This has been made possible by the recent use of a specific enzyme, glucose-oxidase, which is so sensitive as to detect glucose in solution in concentrations as low as 5 mg./100 ml. A commercial preparation, Clinistix (Ames Co.), has been used to detect gl...
متن کاملSimple specific test for urine glucose.
ROCEDURES FOR THE DETECTION OF SUGAR IN URINE are among the oldest tests known in clinical chemistry. Legends going back to earliest times describe the attraction of insects to urine containing sugar. In many instances it is difficult to separate legend from reality in tracing the history of tests for glycosuria. Among such pioneer American clinical chemists as Stanley Benedict, Otto Folin, Vic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 14 11 شماره
صفحات -
تاریخ انتشار 1968