Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique

نویسندگان

  • Yen-Yao Li
  • Tsung-Jen Huang
  • Chin-Chang Cheng
  • Meng-Huang Wu
  • Ching-Yu Lee
چکیده

BACKGROUND Percutaneous vertebroplasty (PV) requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes) during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose the operator or patient to increased radiation dose. The aim of this study was to quantify the amount of radiation exposure to the patient or operator that occurs during PV using one- vs. two-fluoroscopic technique. METHODS Two radiation dosimeters were placed on the right flank of each patient and on the upper sternum of each operator during 26 single-level PV procedures by one senior surgeon. The use of two-fluoroscopic technique (13 patients) and one-fluoroscopic technique (13 patients) were allocated in a consecutive and alternative manner. The operative time and mean radiation dose to each patient and operator were monitored and compared between groups. RESULTS Mean radiation dose to the patient was 1.97±1.20 mSv (95% CI, 0.71 to 3.23) for the one-fluoroscopic technique group vs. 0.95±0.34 mSv (95% CI, 0.85 to 1.23) for the two-fluoroscopic technique group (P=0.031). Mean radiation dose to the operator was 0.27±0.12 mSv (95% CI, 0.17-0.56) for the one-fluoroscopic technique group vs. 0.25±0.14 mSv (95% CI, 0.06-0.44) for the two-fluoroscopic technique group (P=0.653). The operative time was significantly different between groups: 47.15±13.48 min (range, 20-75) for the one-fluoroscopic technique group vs. 36.62±8.42 min (range, 21-50) for the two-fluoroscopic technique group (P=0.019). CONCLUSION Compared to the one-fluoroscopic technique, the two-fluoroscopic technique used during PV provides not only shorter operative times but also reduces the radiation exposure to the patient. There was no significant difference between the two techniques with regards to radiation exposure to the operator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A method of percutaneous vertebroplasty under the guidance of two C-arm fluoroscopes

OBJECTIVE To compare the clinical application in the percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. METHODS One hundred forty three elderly patients with Osteoporotic vertebral compression fractures (OVCFs) underwent percutaneous vertebroplasty under the guidance of one or two C-arm fluoroscopes. The number of pulsed imagings, the time of operation and the in...

متن کامل

A comparison between one- and two-fluoroscopic techniques in percutaneous vertebroplasty

BACKGROUND Percutaneous vertebroplasty (PV) is generally performed under fluoroscopic guidance. Technically, single fluoroscope is considered sufficient for effectively monitoring PV. However, single fluoroscopic technique might be time-consuming in rotating the C-arm of the fluoroscope for either antero-posterior (AP) or lateral radiographic view, and causing delay in detecting cement leakage ...

متن کامل

Significantly reduced radiation dose to operators during percutaneous vertebroplasty using a new cement delivery device

BACKGROUND Percutaneous vertebroplasy (PVP) might lead to significant radiation exposure to patients, operators, and operating room personnel. Therefore, radiaton exposure is a concern. The aim of this study was to present a remote control cement delivery device and study whether it can reduce dose exposue to operators. METHODS After meticulous preoperative preparation, a series of 40 osteopo...

متن کامل

Significantly reduced radiation exposure to operators during kyphoplasty and vertebroplasty procedures: methods and techniques.

BACKGROUND AND PURPOSE Vertebroplasty and kyphoplasty can be associated with significant radiation exposure to the operator. We compared the exposure levels to an operator performing vertebral fracture augmentation with vertebroplasty and kyphoplasty, to assess a cement injection and a monitoring technique designed to reduce this exposure. METHODS A neuroradiologist performed 189 consecutive ...

متن کامل

Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.

BACKGROUND AND PURPOSE Percutaneous vertebroplasty procedures require relatively long durations of fluoroscopic guidance, which might lead to substantial radiation dose to operators. Specialized injection devices have been proposed to limit operator exposure. Our purpose was to compare the radiation dose to the operator's hands during vertebroplasty when using 1-cc syringes versus that when usi...

متن کامل