Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump

نویسندگان

  • Steven G. Imbesi
  • Charles W. Kerber
چکیده

A replica of a lethal wide-necked basilar artery aneurysm was created by casting a deceased patient’s brain vessels and then placing the replica in a circuit of pulsating optically clear non-Newtonian fluid. Individual fluid slipstreams were opacified with isobaric dyes, and images were recorded on film. Studies were completed on the vascular replica, then were repeated, first after placement of a stent across the aneurysm neck and then after placement of Guglielmi detachable coils into the aneurysm sac through the stent. The slipstreams entered the untreated aneurysm via the distal aneurysm neck (the inflow zone), impacting against the distal lateral aneurysm wall. When the stent was placed across the aneurysm neck, the slipstreams lost coherence and did not strike the aneurysm sidewall. Placing the coils further disturbed and reduced aneurysmal flow, especially when the coils filled the inflow zone at the distal lateral aneurysm sac.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens.

SUMMARY A replica of a lethal wide-necked basilar artery aneurysm was created by casting a deceased patient's brain vessels and then placing the replica in a circuit of pulsating optically clear non-Newtonian fluid. Individual fluid slipstreams were opacified with isobaric dyes, and images were recorded on film. Studies were completed on the vascular replica, then were repeated, first after pla...

متن کامل

Analysis of slipstream flow in two ruptured intracranial cerebral aneurysms.

Replicas of ruptured posterior communicating and basilar artery aneurysms were created from cadaveric specimens and then were placed in a circuit of pulsating non-Newtonian fluid. Individual fluid slipstreams were opacified with isobaric dyes, and images were recorded on film. The slipstreams entered the distal aneurysm neck with impact against the distal lateral wall of the aneurysm. They then...

متن کامل

Complete Obliteration of a Basilar Artery Aneurysm after Insertion of a Self-Expandable Leo Stent into the Basilar Artery without Coil Embolization

We report a case of a 45-year-old man who underwent endovascular treatment in the acute setting of a subarachnoid hemorrhage due to rupture of a wide-necked basilar trunk aneurysm. The patient was treated with stent implantation without coiling. A control angiographic scan obtained immediately after the procedure revealed significantly decreased intraaneurysmal flow. Follow-up angiography perfo...

متن کامل

Neuroform stent deployment for treatment of a basilar tip aneurysm via a posterior communicating artery route.

Coiling of a wide-necked basilar tip aneurysm can be accomplished in selected cases by placing a single Neuroform stent horizontally across the aneurysm neck via a posterior communicating artery approach rather than by placing 2 stents in a Y configuration via a basilar artery approach.

متن کامل

Aneurysm flow dynamics: alterations of slipstream flow for neuroendovascular treatment with liquid embolic agents.

BACKGROUND AND PURPOSE The main issue with use of a liquid embolic agent is one of safety. To determine and improve the efficacy of potential neuroendovascular treatment regimens, particularly the use of liquid embolic agents, we evaluated the changes in aneurysm flow dynamics resulting from alterations of parent vessel flow. METHODS We created silicone replicas of a laboratory-created aneury...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001