Morphometrical measurements of resected surface of femurs in Chinese knees: correlation to the sizing of current femoral implants.
نویسندگان
چکیده
Morphometrical data were measured in the resected femurs of seventy Chinese patients who underwent total knee arthroplasties. Two measured parameters, the anterior-posterior length of the lateral condyle and the total width of the distal condyle, were compared to the anterior-posterior length and the medial-lateral width of five femoral implants currently used in Taiwan. Three implants (Duracon, NexGen and UKnee) have a larger medial-lateral width than the total width of the resected distal condyle for a given femoral implant anterior-posterior length. These implants tend to overhang the medial-lateral width of resected femurs from Chinese patients. In addition, one femoral implant (Duracon), which has previously been shown to be suitable for use in Caucasian patients, is not suitable in Chinese patients. Our results will allow manufacturers to design femoral implants better suited to Chinese patients.
منابع مشابه
Correlation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants
of the Caucasian population. The purpose of this study was to investigate the morphometry of the proximal tibia in thestandard resected surface of total knee arthroplasty (TKA).Methods: In this descriptive study, the anthropometric data of the proximal tibia were measured in 132 knees (80 malesand 52 females) using magnetic resonance imaging in 2015. The collected data include...
متن کاملAnthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population
Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...
متن کاملTotal Knee Replacement Sizing: Shoe Size Is a Better Predictor for Implant Size than Body Height
Background: Various sizes of implants need to be available during surgery. The purpose of this paper is to comparebody height and shoe size with implant sizes in patients who underwent total knee replacement surgery to see whichbiomarker is a better predictor for preoperative planning to determine implant size.Methods: A total of 100 knees, belonging to 50 females and 50 males, were observed. P...
متن کاملComparative Study of Sex Differences in Distal Femur Morphology in Osteoarthritic Knees in a Chinese Population
OBJECTIVES The purpose of this study was to investigate sex differences in resected distal femoral morphology in Chinese osteoarthritic knees. METHODS The study included 130 osteoarthritic knees in 65 men and 65 women in China. None had anterior femoral osteophyte or serious patellar femoral joint degeneration. The following were measured using computed tomography and analyzed to identify mor...
متن کاملAnthropometric measurements of knee joints in Thai population: correlation to the sizing of current knee prostheses.
Anthropometric data on the distal femoral condyle and the proximal tibia of 200 knees in 200 Thai subjects were measured using magnetic resonance imaging (MRI). The data including the resected femoral anterior-posterior (AP) length, the resected femoral medial-lateral (ML) width, the resected tibial AP length and the resected tibial ML width were measured. A characterization of the aspect ratio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Knee
دوره 13 1 شماره
صفحات -
تاریخ انتشار 2006