Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

نویسندگان

  • Jianhua Wang
  • Desmond Fonn
  • Trefford L Simpson
  • Lyndon Jones
چکیده

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9.3 years with a mean horizontal K-reading of 7.87 mm. Rigid contact lenses with base curves 0.3- to 0.5-mm steeper than the flattest K of the eye were fitted to measure real corneal thickness (C(2)), independently of the postlens tear film. T was calculated by T = C(1) - C(2). To measure pre- and postlens tear film thickness, Focus Night & Day and Acuvue lenses (Vistakon, Johnson & Johnson Vision Care, Jacksonville, FL) were fitted on both eyes. Central soft lens thickness (L(1)), which includes the prelens tear film (P), was measured by OCT in situ and in saline in a wet cell (L(2)). P was calculated by P = L(1) - L(2). Thickness of the central cornea plus the postlens tear film (C(3)) was measured during lens wearing. Postlens tear film (PLTF) was calculated by PLTF = C(3) - C(2). RESULTS. The mean +/- SD precorneal tear film thickness was 3.3 +/- 1.5 microm (range, 0-6.9) before lens insertion and 4.7 +/- 2.3 microm (range, 0.7-11.0) after lens fitting, which was significantly thicker (paired t-test: P < 0.01). The prelens tear film thickness was 3.9 +/- 2.6 and 3.6 +/- 2.1 microm (mean +/- SD; paired t-test: P = 0.52) and the postlens tear film thickness was 4.5 +/- 2.3 and 4.7 +/- 3.1 microm (paired t-test: P = 0.08) on and under Focus Night & Day and Acuvue lenses, respectively. Post hoc tests showed that precorneal (baseline) and prelens tear films were equivalent, and each was different (thinner; Tukey honestly significant difference P < 0.05) from the postlens tear film. CONCLUSIONS OCT can noninvasively measure the thickness of the precorneal and prelens tear film as well as the postlens tear film. The thickness of the normal precorneal tear film is approximately 3 micro m and becomes thicker after lens fitting. The postlens tear film is thicker than the precorneal and prelens tear films with soft contact lenses. The thickness of both pre- and postlens tear films appears to be independent of the investigated lens types.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Purpose. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). Methods. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before ins...

متن کامل

Measuring of corneal thickness of contact lens wearers with keratoconus and keratoplasty by means of optical coherence tomography (OCT).

To measure the corneal thickness and the depth of the precorneal tear film of contact lens wearers with keratoconus or keratoplasty and to reconfirm the identification and classification of the keratoconus with optical coherence tomography (OCT). The cornea and precorneal tear film of 123 eyes with keratoconus, of 39 eyes after keratoplasty and 8 eyes after LASIK were examined with an OCT (Zeis...

متن کامل

Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry.

PURPOSE To evaluate an interferometric method for measuring the thickness of the pre- (PLTF) and postlens tear film (POLTF) in subjects wearing hydrogel contact lenses. The precision and accuracy of measuring postlens tear thickness is compared with a previous method based on optical pachymetry and mechanical measurement of contact lens thickness. METHODS Reflectance spectra (562-1030 nm) fro...

متن کامل

Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.

PURPOSE To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci. METHODS Forty eyes were imaged with a custom-built, real-time OCT to obtain heights, curvatures, and cross-sectional areas of upper and lower tear menisci simultaneously. The central TFT was indirectly determined as the difference...

متن کامل

Study of human precorneal tear film thickness and structure using laser interferometry.

The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2003