Venous drug-eluting vs. bare-metal stenting: an experimental animal study using frequency domain optical coherence tomography.

نویسندگان

  • Panagiotis M Kitrou
  • Stavros Spiliopoulos
  • Konstantinos Katsanos
  • Stavros Tsantis
  • Athanasios Diamantopoulos
  • Panagiotis Kallidonis
  • Maria Kyriakopoulou
  • George C Kagadis
  • Dimitrios Karnabatidis
  • Dimitrios Siablis
چکیده

INTRODUCTION This protocol was designed to evaluate the safety and feasibility of implanting drug-eluting stents (DES), as well as to compare their long-term results versus bare-metal stents (BMS), in a rabbit venous model, using frequency-domain optical coherence tomography (FD-OCT). METHODS Thirteen New Zealand white rabbits underwent implantation of a zotarolimus-eluting stent in the iliac vein (DES Group) and a BMS in the contralateral iliac vein (BMS Group). The study's primary endpoints included technical success and the comparison of in-stent neointimal hyperplasia in the two study groups, using ex vivo FD-OCT, at 3 months. RESULTS Thirteen DES and 13 BMS were successfully implanted. The technical success rate was 100% (26/26 stents). Three animals (3/13, 23.0%) died within the first 45 days. The remaining 10/13 animals (77%) were euthanized on the 90th day following stent implantation. The 20 stents were successfully removed. Successful ex vivo FD-OCT was performed in all stent-implanted iliac vein segments, 10 in the DES Group and 10 in the BMS Group. There was no statistically significant difference in the mean neointimal thickness between the two groups (3.02 ± 1.19 mm2 in DES Group vs. 2.76 ± 1.17 mm2 in BMS Group; p=0.0501). CONCLUSIONS In this experimental protocol, DES implantation in the venous system was safe and feasible. Hyperplasia thickness was similar in both groups after 3 months' follow up.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravascular ultrasound versus optical coherence tomography guidance.

After the introduction of coronary stenting, intravascular ultrasound (IVUS) was established as the most reliable imaging tool to guide stenting in complex lesions, including coverage of ostial lesions, bifurcation lesions, left main stenting, and chronic total occlusions; and is helpful in determining the cause of stent failures, including in-stent restenosis. These features once verified by I...

متن کامل

INtimal hyPerplasia evAluated by oCT in de novo COROnary lesions treated by drug-eluting balloon and bare-metal stent (IN-PACT CORO): study protocol for a randomized controlled trial

BACKGROUND Neointimal hyperplasia plays a pivotal role in the pathogenesis of in-stent restenosis in patients undergoing percutaneous coronary interventions. Drug-eluting balloons are a promising tool to prevent restenosis after coronary angioplasty. Moreover, an increased knowledge of the pathophysiology of restenosis my help improve therapeutic strategies. METHODS/DESIGN We present the desi...

متن کامل

The Role of Optical Coherence Tomography in Coronary Intervention

Optical coherence tomography (OCT) is an optical analog of intravascular ultrasound (IVUS) that can be used to examine the coronary arteries and has 10-fold higher resolution than IVUS. Based on polarization properties, OCT can differentiate tissue characteristics (fibrous, calcified, or lipid-rich plaque) and identify thin-cap fibroatheroma. Because of the strong attenuation of light by blood,...

متن کامل

Tissue characterization after drug-eluting stent implantation using optical coherence tomography.

OBJECTIVE To validate optical coherence tomography (OCT) imaging for assessment of vascular healing in a preclinical animal model and human autopsy cases and to translate the findings to the assessment of vascular healing after drug-eluting stent implantation in clinical practice. APPROACH AND RESULTS Drug-eluting and bare metal stents were imaged 28 and 42 days after implantation in atherosc...

متن کامل

Late stent malapposition combined by thrombus resolution after primary stenting in acute myocardial infarction: optical coherence tomography findings.

The late stent malapposition (LSM) is defined as a separation of the stent struts from the intima of the coronary artery wall which was not present just after implanting the stent. Although drug-eluting stents (DESs) dramatically reduce the in-stent restenosis, several studies have reported a higher frequency of LSM on follow-up intravascular ultrasound (IVUS) examination after DES implantation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2014