Water distribution system and diarrheal disease transmission: a case study in Uzbekistan.
نویسندگان
چکیده
Deteriorating water treatment facilities and distribution systems pose a significant public health threat, particularly in republics of the former Soviet Union. Interventions to decrease the disease burden associated with these water systems range from upgrading distribution networks to installing reverse osmosis technology. To provide insight into this decision process, we conducted a randomized intervention study to provide epidemiologic data for water policy decisions in Nukus, Uzbekistan, where drinking water quality is suboptimal. We interviewed residents of 240 households, 120 with and 120 without access to municipal piped water. Residents of 62 households without piped water were trained to chlorinate their drinking water at home in a narrow-necked water container with a spout. All study subjects (1583 individuals) were monitored biweekly for self-reported diarrheal illness over a period of 9.5 weeks. The home chlorination intervention group had the lowest diarrheal rate (28.8/1,000 subjects/month) despite lack of access to piped water in their homes. Compared with the two groups that did not receive the intervention this rate was one-sixth that of the group with no piped water (179.2/1,000 subjects/month) and one-third that of the households with piped water (75.5/1,000 subjects/month). More than 30% of the households with piped water lacked detectable levels of chlorine residues in their drinking water, despite two-stage chlorination of the source water, and were at increased risk of diarrhea. Forty-two percent of these municipal users reported that water pressure had been intermittent within the previous two days. The dramatic reduction in diarrheal rates in the home-chlorination intervention group indicates that a large proportion of diarrheal diseases in Nukus are water-borne. The home-chlorination group had less diarrhea than the group with piped water, implicating the distribution system as a source of disease transmission. Taken together, these epidemiologic data would support the hypothesis that diarrhea in the piped water group could be attributed to cross-contamination between the municipal water supply and sewer, due to leaky pipes and lack of water pressure. Relatively inexpensive steps, including chlorination, maintaining water pressure, and properly maintaining the distribution system, rather than reverse osmosis technology, should reduce diarrheal rates.
منابع مشابه
Characterization and Distribution of Virulence Factors in Aeromonas hydrophila Strains Isolated from Fecal Samples of Diarrheal and Asymptomatic Healthy Persons, in Ilam, Iran
Aeromonas hydrophila secretes several extracellular proteins including enterotoxin, hemolysin and aerolysin that are associated with the bacterial virulence. Previous studies have shown that two hemolytic toxins, hemolysin A and aerolysin A contribute to the virulence of Aeromonas hydrophila. In the current study, a total of 50 strains of Aeromonas hydrophila, including 28 (56%) strains isolate...
متن کاملبررسی عوامل محیطی موثر بر بروز اسهال در شهرستان تنگستان استان بوشهر در سال 1390
Background :Diarrhea epidemic happens in most parts of the world especially in developing countries. Accordingly the present study was carried out aiming at surveying the impact of environmental factors on diarrhea incidence in Tangestan Township of Bushehr province in 2012. Method : In this study Case and Control groups were considered. The data were collected by distributing checklists. 2...
متن کاملعوامل موثر بر تداوم موارد اسهالی پس از فاز انفجاری اپیدمی گسترده بیماری اسهالی در استان یزد ـ تابستان 1392: مطالعه مورد شاهدی بر مبنای داده های بُروز
Background and Aim: Water and food born diseases are one of the important causes of morbidity and mortality in through the world. The objective of this study was to investigate factors affecting the persistence of diarrheal cases after the explosive epidemic phase of diarrheal disease in Yazd province. Materials and Methods: We designed a match case control study that was performed on base ...
متن کاملبررسی میزان آلودگی منابع آبی بیمارستانهای شهرخرم آباد به باکتری لژیونلا پنوموفیلا در سال 1387
Background: Legionella is a negative aquatic bacterium and one of the most common nosocomial pathogen. Hospital environment in case of growth, aerosol transmission system and endangered individuals are the high potential location for growth and prevalence of this agent. The suitable temperature in water reservoirs and water distribution system empowered the growth of this bactria. The purpose...
متن کاملDevelopment of a Practical Model for Optimizing Surge Tanks and Air Chambers in Water Transmission Systems
Surge tanks and air chambers are the most useful solution to deal with water hammer in water transmission systems (WTS). The optimal design of these protective devices can be effective in reducing the costs of constructing and operating a water transmission system. In this article, some software with the capability of simulating and optimizing these protective equipment is presented. To simulat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of tropical medicine and hygiene
دوره 59 6 شماره
صفحات -
تاریخ انتشار 1998