Fast optical pH manipulation and imaging.
نویسندگان
چکیده
We describe a complete system for optical pH manipulation and imaging. The system consists of a photoactive Ruthenium complex capable of inducing a change of more than 5 pH units at the nanosecond time scale. A compatible imaging system acquires microscopic pH images at 1200 fps using a nonexpensive commercial digital camera and an LED illumination system. We use the system as a superb tool to investigate flow in Flow Injection Analysis (FIA) models.
منابع مشابه
Optical pH Sensor Based on Quinizarin for Alkaline pH Regions
The development of an optical pH sensor based on immobilization of quinizarin (1,4-dihydroxyanthraquinone) on a triacetylcellulose membrane was described. The resulting membrane exhibited fast color change from yellow to violet, while changing the pH in alkaline region. The immobilized quinizarin showed a broader dynamic range from (pH 9.4-11.4) with respect to free form (pH 8.8-10.4). The sens...
متن کاملOptical manipulation of single flux quanta
Magnetic field can penetrate into type II superconductors in the form of Abrikosov vortices, which are magnetic flux tubes surrounded by circulating supercurrents often trapped at defects referred to as pinning sites. Although the average properties of the vortex matter in superconductors can be tuned with magnetic fields, temperature or electric currents, handling of individual Abrikosov vorti...
متن کاملEngineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)
Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...
متن کاملSingle-exposure optical focusing inside scattering media using binarized time-reversed adapted perturbation
Light scattering inhibits high-resolution optical imaging, manipulation, and therapy deep inside biological tissue by preventing focusing. To form deep foci, wavefront-shaping techniques that break the optical diffusion limit have been developed. For in vivo applications, such focusing must provide a high gain, high speed, and a high focal peak-tobackground ratio. However, none of the previous ...
متن کاملTapered Optical Fiber Coated with ZnO Nanorods for Detection of Ethanol Concentration in Water
This work presents ZnO nanorods coated multimode optical fiber sensing behavior in response to ethanol solution. The sensor operates based on modulation of light intensity which arises from manipulation of light interaction with the ambient environment in sensing region. For this purpose, two steps are experimentally applied here; etching and then coating fiber with ZnO nanorods to provide stro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 84 13 شماره
صفحات -
تاریخ انتشار 2012