Safety and effectiveness of transvenous lead extraction in elderly patients.

نویسندگان

  • Andrzej Kutarski
  • Anna Polewczyk
  • Krzysztof Boczar
  • Andrzej Ząbek
  • Maciej Polewczyk
چکیده

BACKGROUND There is a considerable controversy regarding safety of transvenous lead extraction (TLE) in elderly patients due to their potentially worse general condition, more concomitant diseases, more difficult sedation or analgesia. Moreover, the present experience is not relevant. The aim of the study was the comparison of safety and feasibility of TLE in elderly and middle-aged patients. METHODS We have extracted an ingrown pacemaker (PM)/implantable cardioverter-defibrillator (ICD) leads from 1,060 adult patients (21-70 years) and 192 octogenarians (mean age 83.4 ± 3.1 years) using standard mechanical systems within the last 7 years. We compared effectiveness and complications of the TLE procedures in the two mentioned groups of patients. RESULTS There were more women in octogenarians referred for TLE (45.3% vs. 36.9%). In addition, more pocket infections (37.0% vs. 24.5%), less non-infective indications for PM (46.9% vs. 57.7%) and ICD systems (7.3% vs. 28.8%) TLE were observed in this group. Leads body dwelling time was similar (76.4 ± 56.8 vs. 83.5 ± 63.0) in both groups. Procedure efficacy (full radiological success 97.4% vs. 94.6%, partial radiological success 2.6% vs. 4.34%), safety measures (major complications 1.6% vs. 1.51%, minor complications 1.0% vs. 1.9%) were similar in both compared groups. CONCLUSIONS Old age does not influence TLE effectiveness. Therefore, TLE can be safely and successfully performed in octogenarians.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leads dislodged into the pulmonary vascular bed in patients with cardiac implantable electronic devices

INTRODUCTION Spontaneous lead dislodgement into the pulmonary circulation is a rare complication of permanent pacing with unproven harmfulness and an indication of controversial class for transvenous lead extraction (TLE). AIM To assess TLE safety in patients with leads dislodged into the pulmonary artery. MATERIAL AND METHODS A retrospective analysis of a 9-year-old database of transvenous...

متن کامل

The effectiveness of transvenous leads extractions implanted more than 10 years before.

BACKGROUND The increasing number of patients with cardiac implantable electronic devices (CIEDs) causes a rise in the absolute percentage of individuals qualifying for a transvenous lead extraction (TLE) due to infectious, vascular or lead failure related indications. As the survival time prolongs, TLE procedures more and more often concern the electrodes of long- -term functioning. Authors pro...

متن کامل

Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction

BACKGROUND AND OBJECTIVES The number of patients with cardiac implantable electronic devices needing lead extraction is increasing for various reasons, including infections, vascular obstruction, and lead failure. We report our experience with transvenous extraction of pacemaker and defibrillator leads via the inferior approach of using a gooseneck snare as a first-line therapy and compare extr...

متن کامل

Outcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves.

BACKGROUND Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. METHODS AND RESULTS We retrospectively screened 794 transvenous lead e...

متن کامل

One-Year Follow-Up of Patients Undergoing Transvenous Extraction of Pacemaker and Defibrillator Leads

INTRODUCTION The number of pacemaker and ICD implantations has increased substantially in the recent years. Therefore, complications are also observed in a greater number. In many cases, transvenous extraction of the previously implanted device (pacemaker or ICD) is the only solution. One may find in the literature information about the efficacy and safety of that procedure, but data concerning...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cardiology journal

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2014