Cost-effectiveness comparison of three methods of internal fixation for arthrodesis of the first metatarsophalangeal joint.

نویسندگان

  • A D Watson
  • A S Kelikian
چکیده

We used decision-analysis modeling to determine the most cost-effective fixation device among Herbert screws, AO screws, and the Luhr plate for first metatarsophalangeal joint arthrodesis. The model considered patient-reported outcomes at minimum 2-year follow-up, patient charges for the entire course of care, and event and outcome incidences within each fixation group. AO screws had the lowest average cost of utility and, therefore, are the most cost-effective fixation device for first metatarsophalangeal joint arthrodesis even though utility is highest with the Luhr plate. Operating room costs and union rate most strongly influenced cost-effectiveness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw.

BACKGROUND Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. There are still few comparable clinical data regarding this procedure. In this study we aimed to compare the clinical and radiographical outcomes of crossed-screws, locking and non-locking plate fixation with lag screw for first metatarsophalangeal joint arthrodesis. METHODS A total...

متن کامل

Arthrodesis of the first metatarsophalangeal joint.

Arthrodesis of the first metatarsophalangeal joint is indicated in patients with symptomatic arthrodesis or advanced hallux valgus deformities that are unresponsive to nonsurgical treatment. Several fixation techniques have been described, including intefragmentary compression screws and/or dorsal plate fixation. Using these modern fixation techniques, the rate of fusion is between 94% to 98%, ...

متن کامل

Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 1998