The self-tapping and ICE 3i implants: a prospective 3-year multicenter evaluation.

نویسندگان

  • M Davarpanah
  • H Martinez
  • J F Tecucianu
  • G Alcoforado
  • D Etienne
  • R Celletti
چکیده

This multicenter prospective clinical evaluation was undertaken to determine the therapeutic success and marginal bone level stability of 3i's self-tapping and ICE implants after 3 years of prosthetic loading. Between July 1995 and June 1996, 189 completely or partially edentulous patients were treated with 614 machined-surface screw-type commercially pure titanium implants (self-tapping or ICE). Two hundred seventy-seven self-tapping implants were placed in 85 patients (average age of 56 years), and 337 ICE implants were placed in 104 patients (average age of 61 years). A total of 360 implants (58.6%) were placed in posterior segments. Easier placement was reported with the ICE implant in normal or dense bone. For the self-tapping implants, survival rates of 92.9% and 91.6% were noted after 1 and 3 years of prosthetic loading, respectively. Survival rates of 95.4% and 93.8% were obtained with the ICE implant for the same periods. Late failures (after loading) were more common than early failures (before loading) for both types of implants. The marginal bone level of 238 self-tapping implants (85.9%) and of 307 ICE implants (91%) was radiographically evaluated at 3 years. Marginal bone level was at the first thread for 95.1% of implants. A loss of marginal bone level of 2 to 4 threads was noted for 4.9% of the evaluated implants. No implant showed bone loss greater than the fourth thread. Overall survival rates of 94.3% and 92.9% were obtained after 1 and 3 years of prosthetic loading, respectively, for 596 and 588 implants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective multicenter evaluation of 1,583 3i implants: 1- to 5-year data.

PURPOSE The purpose of this prospective multicenter study was to evaluate the efficacy of 3i threaded implants for the treatment of edentulous patients in a 1- to 5-year period. This article reports the total data and global results of 3 threaded designs of 3i implants: self-tapping, ICE, and Osseotite. MATERIALS AND METHODS A total of 1,583 implants (619 ICE, 545 Osseotite, and 419 self-tapp...

متن کامل

A prospective multicenter clinical trial of 3i machined-surface implants: results after 6 years of follow-up.

PURPOSE In this prospective multicenter clinical study, 1,179 3i standard threaded and self-tapping implants were followed for up to 6 years and monitored according to established success criteria. MATERIALS AND METHODS A total of 493 patients (240 men and 253 women) with a mean age of 45.1 years at implant surgery were enrolled at 6 research centers after being screened for exclusion criteri...

متن کامل

Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study

Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2001