xCELLigence system for real-time label-free monitoring of growth and viability of cell lines from hematological malignancies

نویسندگان

  • Jordi Martinez-Serra
  • Antonio Gutierrez
  • Saúl Muñoz-Capó
  • María Navarro-Palou
  • Teresa Ros
  • Juan Carlos Amat
  • Bernardo Lopez
  • Toni F Marcus
  • Laura Fueyo
  • Angela G Suquia
  • Jordi Gines
  • Francisco Rubio
  • Rafael Ramos
  • Joan Besalduch
چکیده

The xCELLigence system is a new technological approach that allows the real-time cell analysis of adherent tumor cells. To date, xCELLigence has not been able to monitor the growth or cytotoxicity of nonadherent cells derived from hematological malignancies. The basis of its technology relies on the use of culture plates with gold microelectrodes located in their base. We have adapted the methodology described by others to xCELLigence, based on the pre-coating of the cell culture surface with specific substrates, some of which are known to facilitate cell adhesion in the extracellular matrix. Pre-coating of the culture plates with fibronectin, compared to laminin, collagen, or gelatin, significantly induced the adhesion of most of the leukemia/lymphoma cells assayed (Jurkat, L1236, KMH2, and K562). With a fibronectin substrate, nonadherent cells deposited in a monolayer configuration, and consequently, the cell growth and viability were robustly monitored. We further demonstrate the feasibility of xCELLigence for the real-time monitoring of the cytotoxic properties of several antineoplastic agents. In order to validate this technology, the data obtained through real-time cell analysis was compared with that obtained from using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide method. This provides an excellent label-free tool for the screening of drug efficacy in nonadherent cells and discriminates optimal time points for further molecular analysis of cellular events associated with treatments, reducing both time and costs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The xCELLigence system for real-time and label-free analysis of neuronal and dermal cell response to equine herpesvirus type 1 infection.

Real-time cell electronic sensing (RT-CES) based on impedance measurements is an emerging technology for analyzing the status of cells in vitro. It allows label-free, real time monitoring of the biological status of cells. The present study was designed to assess dynamic data on the cell processes during equine herpesvirus type 1 (EHV-1) infection of ED (equine dermal) cells and primary murine ...

متن کامل

Comparison of Cell Viability and Embryoid Body Size of Two Embryonic Stem Cell Lines After Different Exposure Times to Bone Morphogenetic Protein 4

Background: Activation of bone morphogenetic protein 4 (BMP4) signaling pathway in embryonic stem (ES) cells plays an important role in controlling cell proliferation, differentiation, and apoptosis. Adverse effects of BMP4 occur in a time dependent manner; however, little is known about the effect of different time exposure of this growth factor on cell number in culture media. In this study, ...

متن کامل

Evaluation of Impedance-Based Label-Free Technology as a Tool for Pharmacology and Toxicology Investigations

The use of label-free technologies based on electrical impedance is becoming more and more popular in drug discovery. Indeed, such a methodology allows the continuous monitoring of diverse cellular processes, including proliferation, migration, cytotoxicity and receptor-mediated signaling. The objective of the present study was to further assess the usefulness of the real-time cell analyzer (RT...

متن کامل

Improved Cellular Analysis for the Early Detection of Compound-Induced Hepatic Cytotoxicity to Reduce Animal Testing

Most conventional cell-based in vitro assays for the assessment of cell viability and cytotoxicity are disruptive endpoint assays requiring cell lysis. A non-invasive and label-free way to continuously monitor cellular behavior can now be achieved using the xCELLigence System of Real-Time Cell Analyzers (RTCA) co-developed by Roche and ACEA Biosciences (2). xCELLigence RTCA SP, MP and DP Instru...

متن کامل

Expression Status of UBE2Q2 in Colorectal Primary Tumors and Cell Lines

Background: Activation of the ubiquitin-proteasome pathway in various malignancies, including colorectal cancer, is established. This pathway mediates the degradation of damaged proteins and regulates growth and stress response. The novel human gene, UBE2Q2, with a putative ubiquitin-conjugating enzyme activity, is reported to be overexpressed in some malignancies. We sought to investigate the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014