Physiologic compensation is supranormal in compensated aortic stenosis: does it return to normal after aortic valve replacement or is it blunted by coexistent coronary artery disease? An intramyocardial magnetic resonance imaging study.
نویسندگان
چکیده
BACKGROUND In compensated aortic stenosis (AS), cardiac performance measured at the ventricular chamber is typically supranormal, whereas measurements at the myocardium are often impaired. We investigated intramyocardial mechanics after aortic valve replacement (AVR) and the effects relative to the presence or absence of coronary artery disease (CAD+ or CAD-), respectively. METHODS AND RESULTS Twenty-nine patients (46 to 91 years, 10 female) with late but not decompensated AS underwent cardiovascular MRI before AVR (PRE), with follow-up at 6+/-1 (EARLY) and 13+/-2 months (LATE) to determine radiofrequency tissue-tagged left ventricle (LV) transmural circumferential strain, torsion, structure, and function. At the myocardial level, concentric LV hypertrophy regressed 18% LATE (93+/-22 versus 77+/-17 g/m2; P<0.0001), whereas at the LV chamber level, ejection fraction was supranormal PRE, 67+/-6% (ranging as high as 83%) decreasing to 59+/-6% LATE (P<0.05), representing not dysfunction but a return to more normal LV physiology. Between the CAD+ and CAD- groups, intramyocardial strain was similar PRE (19+/-10 versus 20+/-10) but different LATE, with dichotomization specifically related to the CAD state. In the CAD- patients, strain increased to 23+/-10% (+20%), whereas in CAD+ patients it fell to 16+/-11% (-26%), representing a nearly 50% decline after AVR (P<0.05). This was particularly evident at the apex, where CAD- strain LATE improved 17%, whereas for CAD+ it decreased 2.5-fold. Transmural strain and myocardial torsion followed a similar pattern, critically dependent on CAD. AVR impacted LV geometry and mitral apparatus, resulting in decreased mitral regurgitation, negating the double valve consideration. CONCLUSIONS In AS patients after AVR, reverse remodeling of the supranormal systolic function parallels improvement in cardiovascular MRI-derived regression of LV hypertrophy and LV intramyocardial strain. However, discordant effects are evident after AVR, driven by CAD status, suggesting that the typical AVR benefits are experienced disproportionately by those without CAD and not by those obliged to undergo concomitant coronary artery bypass grafting/AVR.
منابع مشابه
High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملCorrelation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study
Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...
متن کاملMyocardial steatosis and left ventricular contractile dysfunction in patients with severe aortic stenosis.
BACKGROUND Aortic stenosis (AS) leads to left ventricular (LV) hypertrophy and dysfunction. We hypothesized that cardiac steatosis is involved in the pathophysiology and also assessed whether it is reversible after aortic valve replacement. METHODS AND RESULTS Thirty-nine patients with severe AS (symptomatic=25, asymptomatic=14) with normal LV ejection fraction and no significant coronary art...
متن کاملAdenosine stress native T1 mapping in severe aortic stenosis: evidence for a role of the intravascular compartment on myocardial T1 values
BACKGROUND Myocardial T1 relaxation times have been reported to be markedly abnormal in diverse myocardial pathologies, ascribed to interstitial changes, evaluated by T1 mapping and calculation of extracellular volume (ECV). T1 mapping is sensitive to myocardial water content of both intra- and extracellular in origin, but the effect of intravascular compartment changes on T1 has been largely n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 112 9 Suppl شماره
صفحات -
تاریخ انتشار 2005