The application of robotics to microlaryngeal laser surgery.

نویسندگان

  • Robert A Buckmire
  • Yu-Tung Wong
  • Allison M Deal
چکیده

OBJECTIVES/HYPOTHESIS To evaluate the performance of human subjects, using a prototype robotic micromanipulator controller in a simulated, microlaryngeal operative setting. STUDY DESIGN Observational cross-sectional study. METHODS Twenty-two human subjects with varying degrees of laser experience performed CO2 laser surgical tasks within a simulated microlaryngeal operative setting using an industry standard manual micromanipulator (MMM) and a prototype robotic micromanipulator controller (RMC). Accuracy, repeatability, and ablation consistency measures were obtained for each human subject across both conditions and for the preprogrammed RMC device. RESULTS Using the standard MMM, surgeons with >10 previous laser cases performed superior to subjects with fewer cases on measures of error percentage and cumulative error (P = .045 and .03, respectively). No significant differences in performance were observed between subjects using the RMC device. In the programmed (P/A) mode, the RMC performed equivalently or superiorly to experienced human subjects on accuracy and repeatability measures, and nearly an order of magnitude better on measures of ablation consistency. The programmed RMC performed significantly better for repetition error when compared to human subjects with <100 previous laser cases (P = .04). CONCLUSIONS Experienced laser surgeons perform better than novice surgeons on tasks of accuracy and repeatability using the MMM device but roughly equivalently using the novel RMC. Operated in the P/A mode, the RMC performs equivalently or superior to experienced laser surgeons using the industry standard MMM for all measured parameters, and delivers an ablation consistency nearly an order of magnitude better than human laser operators. LEVEL OF EVIDENCE NA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robotic microlaryngeal surgery: a new retractor that provides improved access to the glottis.

Robotic surgery has become the standard of care for many procedures outside of otolaryngology, and now is gaining momentum within our specialty. The robot has several advantages to human hands, including removal of tremor and better access to lesions due to increased degree of movement of the articulated instruments. The glottis has rarely been addressed using robotics because access was previo...

متن کامل

Aprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery

 Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...

متن کامل

Robotic microlaryngeal surgery: feasibility using a newly designed retractor and instrumentation.

OBJECTIVES/HYPOTHESIS Robotic surgery is increasingly used for a variety of head and neck surgical procedures but has yet to be adapted for routine robotic microlaryngeal surgery (RMLS). Current retractor technology is limited by the following: poor tongue retraction, poor oral commissure retraction, poor larynx visualization, and laryngeal blades that do not take advantage of the robot's abili...

متن کامل

Robot-assisted pharyngeal and laryngeal microsurgery: results of robotic cadaver dissections.

OBJECTIVES/HYPOTHESIS Robotic surgery has significant potential in pharyngeal and microlaryngeal surgery. We demonstrate the use of a surgical robot in pharyngeal and microlaryngeal surgery in a cadaver. STUDY DESIGN Six experimental surgical dissections, modeled after commonly performed pharyngeal and microlaryngeal procedures, were performed in a cadaver with a commercially available surgic...

متن کامل

A new anesthetic system for microlaryngeal surgery.

Anesthesia for microlaryngeal surgery creates many obstacles for the anesthesiologist and otolaryngologist. Anesthetic techniques developed to improve surgical exposure have been met with significant limitations and are difficult for the anesthesiologist to monitor. A new subglottic jet ventilation anesthesia system is introduced that meets the needs of the otolaryngologist and the anesthesiolo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 125 6  شماره 

صفحات  -

تاریخ انتشار 2015