Comparison of the PACE 2 assay, two amplification assays, and Clearview EIA for detection of Chlamydia trachomatis in female endocervical and urine specimens.

نویسندگان

  • T L Lauderdale
  • L Landers
  • I Thorneycroft
  • K Chapin
چکیده

Screening for sexually transmitted diseases (STDs) in a greater proportion of sexually active patients has become an accepted protocol by most health care providers. The purpose of this study was to compare the current test methods for detection of Chlamydia trachomatis used at the University of South Alabama, the PACE 2 assay (Gen-Probe) and the Clearview EIA (Wampole Laboratories), with two amplification technologies, the AMP CT (Gen-Probe) and LCx (Abbott) assays. In addition, a number of demographic parameters were ascertained by asking questions at the time of examination as well as for health care provider concerns and preferences. One urine and four endocervical swab specimens were collected in random order from 787 female patients attending one of four obstetrics-gynecology clinics. Eighty-seven percent of patients had no STD-related symptoms. Patients were considered positive for C. trachomatis if three or more assays (swab and/or urine) were positive. Abbott and Gen-Probe confirmed discrepant results by alternate amplified assays. A total of 66 true-positive specimens were detected by use of the combination of endocervical swabs and urine specimens. After discrepant analysis, sensitivities for endocervical swab specimens for the EIA and the PACE 2, LCx, and AMP CT assays were 50, 81, 97, and 100%, respectively. Sensitivities for the LCx and AMP CT assays with urine specimens were 98 and 81%, respectively. The prevalence of C. trachomatis was 8.4%, as determined by amplification technology. Overall, the amplification technologies were the most sensitive methods with either swab (AMP CT assay) or urine (LCx assay) specimens. The PACE 2 assay offered the advantage of a simpler and less expensive assay with acceptable sensitivity. The clearview CT EIA, while yielding a rapid in-office result, had unacceptably low sensitivity. The wide variation in performance with amplification assays with urine specimens as reported in both this study and the literature obviates the need to clarify optimal parameters for this specimen type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of chlamydiazyme, PACE 2, and AMP-CT assays for detection of Chlamydia trachomatis in endocervical specimens.

We conducted a comparative evaluation of the Chlamydiazyme (Abbott Laboratories), PACE 2 (Gen-Probe), and AMP-CT (Gen-Probe) assays for the detection of Chlamydia trachomatis in endocervical samples. Specimens from 787 females were included in the study. The sensitivities of the PACE 2 and Chlamydiazyme assays in comparison to the results of the AMP-CT assay were 79.3 and 63.4%, respectively. T...

متن کامل

COMPARISON OF PCR BASED ASSAY AND CELL CULTURE IN DETECTION OF UROGENITA L CHLAMYDIA TRACHOMATIS INFECTION AND DETERMINATION OF THE INHIBITORY RATE O F SPECIMENS UNDER STUDY

An amplification polymerase chain reaction (PCR) test for the direct detection of Chlamydia trachomatis in urethral and endocervical swab specimens from symptomatic and asymptomatic women and men were compared to standard culture technique. During 6 months, 300 endocervical swab specimens from 205 asymptomatic women (64.4%) and 95 symptomatic women (31.6%), and 187 urethral swab specime...

متن کامل

Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens.

AIMS To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. METHODS Two population groups were tested. For the first population gro...

متن کامل

Comparison of the Clearview Chlamydia, the PACE 2 assay, and culture for detection of Chlamydia trachomatis from cervical specimens in a low-prevalence population.

The Clearview Chlamydia assay (Wampole Laboratories, Cranbury, N.J.), the PACE 2 DNA probe assay (GenProbe, San Diego, Calif.), and culture were compared for their abilities to detect Chlamydia trachomatis from cervical specimens in a population with a low prevalence (3.9%) of chlamydial infections. A consensus reference method was used. The consensus reference method defined a positive specime...

متن کامل

Multicenter Evaluation of the BDProbeTec ET System in Detecting Chlamydia trachomatis and Neisseria gonorrhoeae from Endocervical and Urine Specimens in Women

INTRODUCTION The most prevalent sexually transmitted disease in the United States today is caused by Chlamydia trachomatis and the number of reported cases continues to rise. During 1998 the nation has experienced the first increase in the number of reported cases of gonorrhea following a several year decline in reported cases. The significance of serious complications related to chlamydia and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 1999