Development of the 25-item National Eye Institute Visual Function Questionnaire.

نویسندگان

  • C M Mangione
  • P P Lee
  • P R Gutierrez
  • K Spritzer
  • S Berry
  • R D Hays
چکیده

OBJECTIVE To develop and test the psychometric properties of a 25-item version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). DESIGN Prospective observational cohort study of persons with 1 of 5 chronic eye diseases or low vision who were scheduled for nonurgent visits in ophthalmology practices and a reference sample of persons without eye disease. SETTING Eleven university-based ophthalmology practices and the NEI Clinical Center. PATIENTS Eligible participants had to have 1 of the following eye conditions: age-related cataracts, age-related macular degeneration, diabetic retinopathy, primary open-angle glaucoma, cytomegalovirus retinitis, or low vision from any cause. Seven of the 12 sites also enrolled persons in a reference sample. Reference sample participants had no evidence of underlying eye disease but were scheduled for either screening eye examinations or correction of refractive error. All eligible persons had to be 21 years or older, English speaking, and cognitively able to give informed consent and participate in a health status interview. MEASUREMENTS AND MAIN RESULTS To provide the data needed to create the NEI VFQ-25, all subjects completed an interview that included the 51-item NEI VFQ. Estimates of internal consistency indicate that the subscales of the NEI VFQ-25 are reliable. The validity of the NEI VFQ-25 is supported by high correlations between the short- and long-form versions of the measure, observed between-group differences in scores for persons with different eye diseases of varying severity, and the moderate-to-high correlations between the NEI VFQ-25 subscales that have the most to do with central vision and measured visual acuity. CONCLUSIONS The reliability and validity of the NEI VFQ-25 are comparable to those of the 51-item NEI VFQ field test version of the survey. This shorter version will be more feasible in settings such as clinical trials where interview length is a critical consideration. In addition, preliminary analyses indicate that the psychometric properties of the NEI VFQ-25 are robust for the eye conditions studied; this suggests that the measure will provide reproducible and valid data when used across multiple conditions of varying severity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Brazilian version of the 25-Item National Eye Institute Visual Function Questionnaire: translation, reliability and validity.

PURPOSE To develop and investigate the reliability and validity of a Brazilian version of the 25-Item National Eye Institute Visual Function Questionnaire. METHODS A Brazilian version of the questionnaire was developed and applied to patients with chronic eye diseases and healthy controls. Reliability was assessed by Cronbach's alpha coefficient, intraclass correlation coefficient and interra...

متن کامل

Development of a Chinese version of the National Eye Institute Visual Function Questionnaire (CHI-VFQ-25) as a tool to study patients with eye diseases in Hong Kong.

BACKGROUND To develop a Chinese version of the National Eye Institute Visual Function Questionnaire (CHI-VFQ-25) and to test its reliability and validity in a group of patients with eye diseases in Hong Kong. METHODS The National Eye Institute Visual Function Questionnaire (NEI-VFQ) was translated into Chinese. Patients were recruited from Hong Kong, and their demographic data and visual acui...

متن کامل

Remediating serious flaws in the National Eye Institute Visual Function Questionnaire.

PURPOSE To test the assumption that the National Eye Institute Visual Function Questionnaire (NEI VFQ) measures visual functioning, assess the validity of its subscales, and, if flawed, revise the questionnaire and derive a shortened version with sound psychometric properties. SETTING Flinders Medical Centre, Adelaide, Australia. METHODS Patients from the cataract surgery waiting list self-...

متن کامل

Normative comparison of patient-reported outcomes in patients with noninfectious uveitis.

OBJECTIVE To compare vision-related functioning and health-related quality of life of patients with noninfectious intermediate or posterior uveitis with those of the US general population and normal-vision reference groups. METHODS Secondary analysis of health-related quality of life measures administered at baseline to patients with noninfectious intermediate or posterior uveitis participati...

متن کامل

Relationship between self-reported depression and self-reported visual function in Latinos.

OBJECTIVE To validate and assess the relationship between self-reported depression as measured by a single item on the Medical Outcomes Study Short-Form 12 (SF-12) and self-reported visual function. METHODS The Los Angeles Latino Eye Study is population-based and designed to assess the prevalence of visual impairment, ocular disease, and visual functioning in Latinos. Both the 25-item Nationa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 119 7  شماره 

صفحات  -

تاریخ انتشار 2001