Localization of cochlear implant electrodes in radiographs.
نویسندگان
چکیده
Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programming for better speech recognition. The prerequisite for 3-D localization of the electrodes is their 2-D localization in x-ray radiographs. In this paper, we develop a practical method to localize the electrodes with high efficiency, accuracy, and reproducibility. In this method, a priori knowledge of the electrodes and their approximate positions are utilized, an intelligent thresholding and segmentation mechanism is embedded, and the electrode center is computed as the weighted geometric center of segmented electrode pixels. Experiments with physical phantoms and human data demonstrate the feasibility and utility of this method. The PC-based program developed for this project is disseminated on the Web.
منابع مشابه
Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...
متن کاملPostoperative imaging of the multichannel cochlear implant.
PURPOSE To present the postoperative radiographic appearance of the multichannel cochlear implant and to suggest criteria for the radiographic evaluation of postimplant patients. METHODS One hundred forty-one patients, 73 female and 68 male, had multichannel cochlear implants inserted. One hundred thirty-five intraoperative radiographs, 31 postoperative radiographic examinations, and 10 posto...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملThe effect of reducing the number of electrodes on spatial hearing tasks for bilateral cochlear implant recipients.
BACKGROUND Many studies have documented the effect of reducing spectral information for speech perception in listeners with normal hearing and hearing impairment. While it is understood that more spectral bands are needed for unilateral cochlear implant listeners to perform well on more challenging listening tasks such as speech perception in noise, it is unclear how reducing the number of spec...
متن کاملThe Phonemic Awareness Skills of Cochlear Implant Children and Children with Normal Hearing in Primary School
Objectives: Phonemic awareness skills have a significant impact on children speech and language. The purpose of this study was investigating the phonemic awareness skills of children with cochlear implant and normal hearing peers in primary school. Methods: phonemic awareness subscales of phonological awareness test were administered to 30 children with cochlear implantation at the first to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 27 4 شماره