Therapeutic impact of colon capsule endoscopy with PillCam™ COLON 2 after incomplete standard colonoscopy: a Spanish multicenter study.

نویسندگان

  • Óscar Nogales
  • Javier García-Lledó
  • Marisol Luján
  • David Nicolás
  • José Francisco Juanmartiñena
  • Begoña González-Suárez
  • Francisco Sánchez Ceballos
  • Ignacio Couto
  • José Olmedo
  • Cristina Garfia
  • Cristina Carretero
  • Ignacio Fernández Urién
  • Sarbelio Rodríguez
  • Matilde Asteinza
  • Pilar Olivencia
  • Ángeles Masedo
  • Miguel Muñoz-Navas
  • Beatriz Merino
  • Cecilia González Asanza
چکیده

INTRODUCTION Colon capsule endoscopy (CCE) is an alternative approach for the examination of the colon in patients who refuse colonoscopy or after incomplete colonoscopy (IC). We conducted a study to determine the frequency of complete colonoscopy after IC, the diagnostic yield of CCE, the therapeutic impact of lesions found in CCE, the level of colon cleanliness and the safety of the procedure. METHODS We performed a prospective, multicenter study involving ten Spanish hospitals. Consecutive outpatients aged ≥ 18 years with previous IC were invited to participate. The latest version of the CCE device, PillCam™ COLON 2 (CCE-2), was administered to all patients according to the protocol. RESULTS The study population comprised 96 patients. The most frequent cause of IC was the inability to move past a loop using standard maneuvers (75/96 patients, 78%). Complete visualization of the colon was obtained with CCE-2 in 69 patients (71.9%). Of the 27 patients in whom the CCE-2 did not reach the hemorrhoidal plexus, it passed the colonic segment explored with the previous colonoscopy in 20 cases; therefore, it could be inferred that a combined approach (CCE-2 plus colonoscopy) enabled complete visualization of the colonic mucosa in 92.7% of patients. CCE-2 revealed new lesions in 58 patients (60.4%). Polyps were the most frequent finding (41 patients; 42.7% of the total number of patients). In 43 of the 58 patients (44.8% of the total number of patients), the new lesions observed led to modification of therapy, which included a new colonoscopy for polyp resection or surgery in patients with colonic neoplasm. CONCLUSIONS CCE-2 is a suitable diagnostic procedure that can lead to more frequent diagnosis of significant colonic lesions after IC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colon Capsule Endoscopy: Review and Perspectives

Colon capsule endoscopy utilizing PillCam COLON 2 capsule allows for visualization potentially of the entire colon and is currently approved for patients who cannot withstand the rigors of traditional optical colonoscopy (OC) and associated sedation as well as those that had an OC that was incomplete for technical reasons other than a poor preparation. We will then describe the prior experience...

متن کامل

Second-generation colon capsule endoscopy compared with colonoscopy.

BACKGROUND Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE To assess the feasibility, accu...

متن کامل

Role of colon capsule Pillcam 2 in obscure gastrointestinal bleeding - case report

INTRODUCTION The diagnosis and management of gastrointestinal bleeding have always been a challenge to clinicians. In most patients, the source of bleeding is easily identified during conventional upper and/or lower gastrointestinal endoscopies. A significant progress in the evaluation of patients with obscure gastrointestinal bleeding was brought by the advent of capsule endoscopy. Since colon...

متن کامل

The flat polyp: does too much

panese colleagues. Recently flat polyps have also been recognized in the West and have been noticed to have a higher incidence of significant neoplastic histology [1]. We describe two cases of a flat polyp missed or almost missed at colonoscopy, perhaps due to the effects of full insufflation. A 53-year-old healthy woman participated in a PillCam Colon 2 study in which PillCam Colon 2 capsule e...

متن کامل

Colon capsule endoscopy compared to colonoscopy for colorectal neoplasms diagnosis: an initial experience and a brief review of the literature.

Conventional colonoscopy is regarded as the gold standard procedure for the diagnosis of colorectal neoplasms despite its several limitations including invasiveness, discomfort and potential complications. Colon capsule endoscopy (CCE) could be an attractive alternative method to the invasive colonoscopy for the diagnosis of colorectal cancer and polyps. Publications regarding the use of CCE fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva

دوره 109 5  شماره 

صفحات  -

تاریخ انتشار 2017