Distal locking in femoral intramedullary nailing system: Is one cross screw sufficient?

نویسندگان

  • Saravana Vail Karuppiah
  • Alan Johnstone Johnstone
چکیده

Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the procedure. Objective: This biomechanical study was undertaken to compare the stability of using one distal locking cross screw versus two cross screws in femoral fractures fixed with intramedullary nailing (IMN) system. Materials: A composite model made from a stainless steel IMN (12 mm × 1 mm) was connected to a load cell (Instron machine). Axial forces upto 2 kN (3 times body weight) was applied or until a maximum displacement of 1 mm was reached. The distal locking end of the intramedullary nail was secured with stainless steel cylinders of different dimensions 50 mm × 5 mm, 75 mm × 5 mm and 100 mm × 3 mm to represent the proximal femoral diaphysis, diaphyseo-metaphyseal junction and distal femoral metaphyseal respectively. The distal locking end of the intramedullary nail was attached to the cylinder with a dedicated single or two rods (5 mm diameter), made from stainless steel, to represent the distal locking cross screw. Results: In the 50 mm cylinder, the mean stiffness (±standard deviation) of the system using either single or two screws were similar i.e. 3298 ± 144 N/mm. But in the 75 mm and 100 mm cylinders, the mean stiffness of the fracture model with two distal locking cross screws fixation was 2.059 ± 96 N/mm and 0.816 ± 122 N/mm and with single distal locking cross screw fixation were 0.643 ± 142 N/mm and 0.289 ± 88 N/mm respectively. Conclusion: Single distal locking cross screw fixation provide poorer fracture stability compared to two distal locking cross screws when used to fix distal femoral metaphyseal fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

Simultaneous Use of Cannulated Reamer and Schanz Screw for Closed Intramedullary Femoral Nailing

Introduction. Closed reduction is a critical component of the intramedullary nailing and at times can be difficult and technically challenging resulting in increased operative time. Fluoroscopy is used extensively to achieve closed reduction which increases the intra-operative radiation exposure. Materials and Methods. Sixty patients with femoral diaphyseal fractures treated by locked intramedu...

متن کامل

Intramedullary Nailing of Femoral Shaft Fractures with Compressive Nailing Using Only Distal Dynamic Hole and Proximal Static Hole

Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw. Methods: Forty-three patients who had a fracture of the femoral shaft were managed between 2005 and 2008 with intramedullary nailing and the use of only one screw for distal inter...

متن کامل

Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of femoral intramedullary nails

BACKGROUND Although the method has been used widely, one of the greatest challenges for intramedullary nailing is to position the distal locking screw. A new technology, the electromagnetic navigation system, is a radiation-free way to locate the position of the drill bit and provide 3-dimensional real-time feedback of location and orientation of the drill bit relative to the locking holes. The...

متن کامل

Intramedullary nailing versus locked plate for treating supracondylar periprosthetic femur fractures.

The objective of this study was to compare retrograde intramedullary femoral nailing with supracondylar locked screw-plate fixation for the treatment of periprosthetic femur fractures following total knee arthroplasty. Time to union and full weight bearing were the primary study outcomes, with perioperative blood loss, need for transfusion, need for revision surgery, and infection being the sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013