B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T.
نویسندگان
چکیده
At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.
منابع مشابه
Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA.
BACKGROUND Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the eff...
متن کاملSpectrally Selective B1 Insensitive T2 Preparation Sequence for 3T Imaging
R. Nezafat, J. A. Derbyshire, R. Ouwerkerk, M. Stuber, E. R. McVeigh Lab of Cardiac Energetics, Division of Intramural Research, NHLBI, NIH, DHHS, Bethesda, MD, United States, Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States, Radiology, Johns Hopkins University, Baltimore, MD, United States Introduction: T2 magnetization preparation (T2 Prep) and spectrally selecti...
متن کاملCoronary magnetic resonance imaging after routine implantation of bioresorbable vascular scaffolds allows non-invasive evaluation of vascular patency
BACKGROUND Evaluation of recurrent angina after percutaneous coronary interventions is challenging. Since bioresorbable vascular scaffolds (BVS) cause no artefacts in magnetic resonance imaging (MRI) due to their polylactate-based backbone, evaluation of vascular patency by MRI might allow for non-invasive assessment and triage of patients with suspected BVS failure. METHODS Patients with pol...
متن کاملDesign of an adiabatic T2-preparation method optimized for cardiac motion and flow insensitivity at 3T
Background T2 contrast is important for the assessment of acute myocardial edema and coronary morphology. At 1.5T, the standard T2-prep method uses 4 composite 180° pulses (MLEV4 [1]) providing robust and uniform T2-preparation, but at 3T, increased B1 inhomogeneity causes artifacts. Decreasing inter-pulse spacing improves refocusing in the presence of motion and flow. We developed a configurab...
متن کاملCorrelation between magnetic resonance angiography (MRA) and quantitative coronary angiography (QCA) in ectatic coronary vessels.
Coronary artery ectasia (CAE) is defined as a dilatation of an arterial segment to a diameter at least 1.5 times that of the adjacent normal artery. The correct follow-up of ectatic vessels is hampered by the need for repeat angiograms. In this work we compared quantitative coronary angiography (QCA) measurements of the diameter of the proximal most ectatic part of coronary vessels, with corres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 55 4 شماره
صفحات -
تاریخ انتشار 2006