Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study

نویسندگان

  • Judith Bellapart
  • Shureng Geng
  • Kimble Dunster
  • Daniel Timms
  • Adrian G Barnett
  • Rob Boots
  • John F Fraser
چکیده

BACKGROUND The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and inflation ratio weaning. METHODS Cerebral blood flow was measured using transcranial Doppler, in a convenience sample of twenty patients requiring balloon counterpulsation for refractory cardiogenic shock (N = 7) or a single inotrope to maintain mean arterial pressure following an elective placement of an intra-aortic balloon pump for cardiac surgery (N = 13). Simultaneous blood pressure at the aortic root was recorded via the intra-aortic balloon pump. Cerebral blood flow velocities were recorded for six minute intervals at a 1:1 balloon inflation-ratio (augmentation of all cardiac beats) and during progressive reductions of the inflation-ratio to 1:3 (augmentation of one every third cardiac beat). Real time comparisons of peak cerebral blood flow velocities with systolic blood pressure were performed using cross-correlation analysis. The primary endpoint was assessment of cerebral autoregulation using the time delay between the peak signals for cerebral blood flow velocity and systolic blood pressure, according to established criteria. The variability of cerebral blood flow was also assessed using non-linear statistics. RESULTS During the 1:1 inflation-ratio, the mean time delay between aortic blood pressure and cerebral blood flow was -0.016 seconds (95% CI: -0.023,-0.011); during 1:3 inflation-ratio mean time delay was significantly longer at -0.010 seconds (95% CI: -0.016, -0.004, P < 0.0001). Finally, upon return to a 1:1 inflation-ratio, time delays recovered to those measured at baseline. During inflation-ratio reduction, cerebral blood flow irregularities reduced over time, whilst cerebral blood flow variability at end-diastole decreased in patients with cardiogenic shock. CONCLUSIONS Weaning counterpulsation from 1:1 to 1:3 inflation ratio leads to a progressive reduction in time delays between systolic blood pressure and peak cerebral blood flow velocities suggesting that although preserved, there is a significant delay in the establishment of cerebral autoregulatory mechanisms. In addition, cerebral blood flow irregularities (i.e. surrogate of flow adaptability) decrease and a loss of cerebral blood flow chaotic pattern occurs during the end-diastolic phase of each beat in patients with cardiogenic shock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Paraplegia associated with intraaortic balloon pump counterpulsation.

Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hy...

متن کامل

Basic principles of the intraaortic balloon pump and mechanisms affecting its performance.

The intraaortic balloon pump (IABP) is the single most effective and widely used device for temporary mechanical assistance of the failing heart. Although the principles underlying IABP function are simple, various biologic factors often determine its performance in a particularly complicated way. We briefly describe the basic disciplines of counterpulsation by IABP and the induced hemodynamic ...

متن کامل

Intraaortic balloon counterpulsation in a community hospital.

Our experience with intraaortic balloon counterpulsation in 41 patients documents the feasibility of a coordinated aggressive therapeutic approach in patients with potentially fatal complications of coronary artery disease. The use of intraaortic balloon pump in a non-cardiac surgical center has allowed hemodynamic support in the critically ill, safety in angiography, appropriate selection of p...

متن کامل

Prophylactic intraaortic balloon counterpulsation in high-risk cardiac surgery: a survey of opinion and current practice

INTRODUCTION Patients undergoing cardiac surgery increasingly have greater comorbidities and subsequently are at higher risk of adverse postoperative outcomes. Despite some evidence suggests that prophylactic intraaortic balloon counterpulsation reduces mortality in selected high-risk patients, its use remains low. The aim of this study was to investigate reported management strategies of high-...

متن کامل

Intraaortic Balloon Counterpulsation

After his first acute myocardial infarction, a 69-year-old male suffered the usually lethal complication of ventricular free-wall rupture. Early suspicion of possible rupture and immediate percutaneous insertion of an intraaortic balloon pump assist device afforded sufficient hemodynamic stability to proceed with cardiac catheterization. The diagnosis of ventricular free-wall rupture was confir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010