A comparison of hemodynamic changes after endotracheal intubation by the Optiscope™ and the conventional laryngoscope
نویسندگان
چکیده
BACKGROUND Optiscope™ is a newly developed video stylet device. This study evaluated and compared the hemodynamic changes observed after endotracheal intubation with video stylet and after conventional laryngoscopic endotracheal intubation. METHODS Fifty-eight adult patients with American Society of Anesthesiologists (ASA) physical status class 1 or 2, undergoing general anesthesia, were randomized into two groups: one group of patients were intubated using video stylet (n = 29) and the other group were intubated using direct laryngoscope (n = 29). Systolic blood pressure (SBP), mean arterial pressure (MAP), diastolic blood pressure (DBP), heart rate (HR), POGO (percentage of glottic opening) score, time for intubation and degree of sore throat were recorded. RESULTS There were no significant differences in the SBP, MAP, DBP, HR, and the sore throat incidence between the two groups. Optiscope™ produced better POGO scores, but time for intubation was longer than with conventional laryngoscope. CONCLUSIONS Optiscope™, when compared with conventional laryngoscope for intubation, does not modify the hemodynamic response, but it provides a better view of the vocal cords.
منابع مشابه
Comparison of hemodynamic changes in patients using conventional laryngoscopy and video laryngoscope in surgery
Introduction: One of the complications of laryngoscopy and endotracheal intubation is sympathetic stimulation with hemodynamic changes that are always tried to be avoided by anesthesiologists. The aim of this study is to review and compare hemodynamic changes caused by both conventional and video laryngoscopy. Methods: In this clinical trial performed in 2015 in the Birjand-based Imam Reza Hosp...
متن کاملEvaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملOptiscope® may have less stimulation on hemodynamic changes
This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. CC Ko et al. [1] described that the Optiscope for tracheal intubation did not reduce the ...
متن کاملEvaluation of Mexiletine Effect on Bispectral Index Changes and Hemodynamic Responses to Endotracheal Intubation and During General Anesthesia
Background &Objective: Plaryngoscopy and tracheal intubation increase not only blood pressure and heart rate but also Bispectral Index (BIS) of the patients. In this study, hemodynamic and BIS changes were surveyed after tracheal intubation and during general anesthesia followed by mexiletine prescription . Materials & Methods: In this study, 50 patients aged between 20 and 60 who were ca...
متن کامل