Corrosion and adverse tissue reaction after modular unipolar hip hemiarthroplasty

نویسندگان

  • Brian F. Moore
  • Paul F. Lachiewicz
چکیده

Modern unipolar hip hemiarthroplasty, commonly used for displaced femoral neck fracture, is now modular, with both a variable length cobalt-chromium adapter-sleeve and large femoral head. Patients with these modular components may develop symptomatic trunnion corrosion, with elevated serum metal levels. We report the case of an 82-year-old woman, 5.5 years after a modular unipolar hip hemiarthroplasty, who presented with a 4-month history of hip pain and limp. Evaluation showed elevated serum cobalt and chromium levels and an acetabular cyst. At revision, fluid, tissue, and gross inspection were consistent with trunnion corrosion. The hip was revised with a ceramic head and dual mobility acetabular component, with a good result at 1 year. The designs of commercially available, modern unipolar hip hemiarthroplasty prostheses are reviewed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adverse reaction to metal debris in a painful hemiarthroplasty of the hip

Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all ...

متن کامل

Thompson hemiarthroplasty versus modular unipolar implants for patients requiring hemiarthroplasty of the hip

OBJECTIVES The objective of this study was to assess all evidence comparing the Thompson monoblock hemiarthroplasty with modular unipolar implants for patients requiring hemiarthroplasty of the hip with respect to mortality and complications. METHODS A literature search was performed to identify all relevant literature. The population consisted of patients undergoing hemiarthroplasty of the h...

متن کامل

Unipolar versus Bipolar Uncemented Modular Hemiarthroplasty in Patients with Displaced Femoral Neck Fractures: a Three-year Follow-up

Objective: Fractures of neck of femur are common fractures in the elderly. To keep up an imperative distance from the poor results of internal fixation and early ambulation of patients, hemiarthroplasty is performed. There is a lacking evidence to bolster the choice between unipolar or bipolar hemiarthroplasty, let alone the modularity of modern components. The objective of this study was to as...

متن کامل

Hip dislocation after modular unipolar hemiarthroplasty.

An institutional review board-approved retrospective review of hip fractures in elderly patients treated with a modular unipolar implant was carried out to identify factors predisposing to dislocation of a hemiarthroplasty. The main outcome measure evaluated was dislocation vs nondislocation. Two hundred seventeen patients underwent the surgery, and 174 were available for review at 6 weeks and ...

متن کامل

Corrosion and adverse local tissue reaction after total hip arthroplasty with a modular titanium alloy femoral neck

This report describes a case of mechanically assisted crevice corrosion and secondary adverse local tissue reaction in a patient following a total hip arthroplasty, utilizing a modular neck (bi-modular) femoral component. Radiographic evaluation demonstrated a well-positioned, stable, cementless arthroplasty. Upon further evaluation, the patient had elevated serum cobalt and chromium levels, an...