INTRODUCTION Forward deployed military medical units can provide sophisticated medical care with limited resources. Point-of-Care Testing (POCT) may facilitate care and expedite diagnosis. This study assessed the accuracy of results for POCT for non-serum samples (pleural, peritoneal, and cerebrospinal fluid) using iSTAT and Piccolo hand-held devices compared with results obtained using a hospital chemistry analyzer. METHODS Pleural, peritoneal, and cerebrospinal fluids obtained during routine care were simultaneously analyzed on a Vitros 5600 automated clinical chemistry hospital analyzer, iSTAT, and Piccolo POCT devices. RESULTS POCT results were highly correlated with the Vitros 5600 for pleural fluid LDH, glucose, and triglycerides (TG); for peritoneal fluid bilirubin, TG, glucose, albumin, and protein; and glucose for cerebrospinal fluid. CONCLUSION POCT results for non-serum samples from pleural, peritoneal, and cerebrospinal fluid correlate with standard hospital chemistry analysis. The results of this study demonstrate potential for possible new diagnostic roles for POCT in resource-limited environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of liver function tests on Piccolo Xpress point of care chemistry analyzer in a pediatric hospital

OBJECTIVES Point of care testing (POCT) contributes to diagnosis and monitoring with fast testing time and easily performed assays. We evaluated the Abaxis Piccolo Xpress point of care chemistry analyzer using the Liver Panel Plus discs for our pediatric patient population at Texas Children's Hospital. DESIGN AND METHODS Analytical performance was evaluated for precision and linearity using q...

متن کامل

Lactate point-of-care testing for acidosis: Cross-comparison of two devices with routine laboratory results

OBJECTIVES Lactate is a major parameter in medical decision making. During labor, it is an indicator for fetal acidosis and immediate intervention. In the Emergency Department (ED), rapid analysis of lactate/blood gas is crucial for optimal patient care. Our objectives were to cross-compare-for the first time-two point-of-care testing (POCT) lactate devices with routine laboratory results using...

متن کامل

Dynamic Analysis of Offshore Wind Turbine Towers with Fixed Monopile Platform Using the Transfer Matrix Method

In this paper, an analytical method for vibrations analysis of offshore wind turbine towers with fixed monopile platform is presented. For this purpose, various and the most general models including CS, DS and AF models are used for modeling of wind turbine foundation and axial force is modeled as a variable force as well. The required equations for determination of wind turbine tower response ...

متن کامل

Identifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test

Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hawai'i journal of medicine & public health : a journal of Asia Pacific Medicine & Public Health

دوره 73 9 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2014