Osteon pullout in the equine third metacarpal bone: effects of ex vivo fatigue.

نویسندگان

  • L P Hiller
  • S M Stover
  • V A Gibson
  • J C Gibeling
  • C S Prater
  • S J Hazelwood
  • O C Yeh
  • R B Martin
چکیده

An important concept in bone mechanics is that osteons influence mechanical properties in several ways, including contributing to toughness and fatigue strength by debonding from the interstitial matrix so as to "bridge" developing cracks. Observations of "pulled out" osteons on fracture surfaces are thought to be indicative of such behavior. We tested the hypothesis that osteon pullout varies with mode of loading (fatigue vs. monotonic), cortical region, elastic modulus, and fatigue life. Mid-diaphseal beams from the dorsal, medial, and lateral regions of the equine third metacarpal bone were fractured in four point bending by monotonic loading to failure under deflection control, with or without 10(5) cycles of previous fatigue loading producing 5000 microstrain (15-20% of the expected failure strain) on the first cycle; or sinusoidal fatigue loading to failure, under load or deflection control, with the initial cycle producing 10,000 microstrain (30-40% of the expected failure strain). Using scanning electron microscopy, percent fracture surface area exhibiting osteon pullout (%OP.Ar) was measured. Monotonically loaded specimens and the compression side of fatigue fracture surfaces exhibited no osteon pullout. In load-controlled fatigue, pullout was present on the tension side of fracture surfaces, was regionally dependent (occurring to a greater amount dorsally), and was correlated negatively with elastic modulus and positively with fatigue life. Regional variation in %OP.Ar was also significant for the pooled (load and deflection controlled) fatigue specimens. %OP.Ar was nearly significantly greater in deflection controlled fatigue specimens than in load-controlled specimens (p=0.059). The data suggest that tensile fatigue loading of cortical bone eventually introduces damage that results in osteonal debonding and pullout, which is also associated with increased fatigue life via mechanisms that are not yet clear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osteon interfacial strength and histomorphometry of equine cortical bone.

The interfacial strength of secondary osteons from the diaphysis of the Thoroughbred equine third metacarpal was evaluated using the fiber pushout test. The pushout was performed on 300-500 microm sections of 4x4x15 mm bone blocks machined from four anatomic regions of the cortex. Pushout strength was evaluated from proximal to distal location within the diaphysis on four osteon types classifie...

متن کامل

Osteonal effects on elastic modulus and fatigue life in equine bone.

We hypothesized that recently formed, incompletely mineralized, and thus, relatively deformable osteons in the equine third metacarpus enhance in vitro load-controlled fatigue life in two ways. Macroscopically, there is a compliance effect, because reduced tissue elastic modulus diminishes the stress required to reach a given strain. Microscopically, there is a cement line effect, in which new ...

متن کامل

Osteonal structure in the equine third metacarpus.

In studying the flexural fatigue properties of the equine third metacarpal (cannon) bone, we previously found that the dorsal region was weaker monotonically, but more fatigue resistant, than the lateral region. Fatigue resistance was associated with fracture surfaces which demonstrated that secondary osteons had "pulled out" of the surrounding matrix; this never happened in lateral specimens. ...

متن کامل

Interpreting cortical bone adaptation and load history by quantifying osteon morphotypes in circularly polarized light images.

Birefringence variations in circularly polarized light (CPL) images of thin plane-parallel sections of cortical bone can be used to quantify regional differences in predominant collagen fiber orientation (CFO). Using CPL images of equine third metacarpals (MC3s), R.B. Martin, V.A. Gibson, S.M. Stover, J.C. Gibeling, and L.V. Griffin. (40) described six secondary osteon variants ('morphotypes') ...

متن کامل

A weighted osteon morphotype score outperforms regional osteon percent prevalence calculations for interpreting cortical bone adaptation.

Using circularly polarized light microscopy,we described a weighted-scoring method for quantifying regional distributions of six secondary osteon morphotypes(Skedros et al.: Bone 44 (2009) 392-403). This osteon morphotype score (MTS) strongly correlated with "tension" and "compression" cortices produced by habitual bending. In the present study, we hypothesized that the osteon MTS is superior t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2003