Photofunctionalized dental implants: a case series in compromised bone.

نویسندگان

  • Akiyoshi Funato
  • Takahiro Ogawa
چکیده

PURPOSE Ultraviolet (UV) light treatment of titanium, or photofunctionalization, has been shown to enhance its osteoconductivity in animal and in vitro studies, but its clinical performance has yet to be reported. This clinical case series sought to examine the effect of photofunctionalization on implant success, healing time, osseointegration speed, and peri-implant marginal bone level changes at 1 year after restoration. MATERIALS AND METHODS Four partially edentulous patients were included in the study. Seven implants with identical microroughened surfaces were photofunctionalized with UV light for 15 minutes. Osseointegration speed was calculated by measuring the increase in implant stability quotient (ISQ) per month. Marginal bone levels were evaluated radiographically at crown placement and at 1 year. RESULTS All implants placed into fresh extraction sockets, vertically augmented bone, simultaneously augmented sinuses, or the site of a failing implant remained functional and healthy at 1 year, even with an earlier loading protocol (2.1 to 4.5 months). ISQs of 48 to 75 at implant placement had increased to 68 to 81 at loading. In particular, implants with low primary stability (initial ISQ < 70) showed large increases in ISQ. The speed of osseointegration of photofunctionalized implants was considerably greater than that of as-received implants documented in the literature. Mean marginal bone levels were -0.35 ± 0.71 mm at crown placement and had significantly increased to 0.16 ± 0.53 mm at 1 year, with coronal gains in marginal bone level that surpassed the implant platform. No implants showed marginal bone loss. CONCLUSIONS Within the limits of this study, photofunctionalization expedited and enhanced osseointegration of commercial dental implants in various clinically challenging/compromised bone conditions. Photofunctionalization resulted in preservation--and often a gain--of marginal bone level, and long-term large-scale clinical validation is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Implant stability change and osseointegration speed of immediately loaded photofunctionalized implants.

OBJECTIVES This study evaluated the degree and rate of implant stability development for photofunctionalized dental implants in humans. MATERIALS AND METHODS Thirty-three implants (7 patients) placed in the maxilla and immediate loaded were evaluated. Photofunctionalization was performed by treating implants with ultraviolet for 15 minutes immediately before placement. Implant stability was a...

متن کامل

Success rate, healing time, and implant stability of photofunctionalized dental implants.

PURPOSE This is the first study to report the clinical outcomes of photofunctionalized dental implants. MATERIALS AND METHODS This retrospective study analyzed 95 consecutive patients who received 222 untreated implants and 70 patients who received 168 photofunctionalized implants over a follow-up period of 2.5 years. Photofunctionalization was performed by treating implants with UV light for...

متن کامل

Bone Generation Profiling Around Photofunctionalized Titanium Mesh.

PURPOSE The aim of this study was to evaluate whether photofunctionalization of titanium mesh enhances its osteoconductive capability. MATERIALS AND METHODS The titanium mesh (0.2 mm thickness) used in this study was made of commercially pure grade-2 titanium and had hexagonal apertures (2 mm width). Photofunctionalization was performed by treating titanium mesh with UV light for 12 minutes u...

متن کامل

The Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs

  Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2013