PURPOSE To provide a comprehensive review of clinical outcomes and retear rates after patch use in rotator cuff repair, and to determine the differences between available graft types and techniques. METHODS A systematic review was conducted from database (PubMed, Medline, Scopus, Embase) inception to January 2015 for English-language articles reporting outcome data with 9 months' minimum follow-up. Studies were assessed by 2 reviewers who collected pertinent data, with outcomes combined to generate frequency-weighted means. RESULTS Twenty-four studies met the inclusion criteria. The frequency-weighted mean age was 61.9 years with 35.4 months' follow-up. The mean improvements in postoperative range of motion in the forward elevation, abduction, external rotation, and internal rotation planes were 58.6°, 66.2°, 16.6°, and 16.1°, respectively, and postoperative abduction strength improved by 3.84 kg. American Shoulder and Elbow Surgeons, University of California-Los Angeles, Constant, Penn, and Oxford scores improved by 39.3, 10.7, 40.8, 34.4, and 17.6, respectively. Augmentation and interposition techniques showed similar improvements in range of motion, strength, and patient-reported outcomes (PROs), whereas xenografts showed less improvement in PROs compared with other graft types. Studies reported improvements in pain and activities of daily living (ADLs), with greater than 90% overall satisfaction, although few patients (13%) were able to return to preinjury activity. Whereas interposition and augmentation techniques showed similar improvements in pain and ADLs, xenografts showed less improvement in ADLs than other graft types. The overall retear rate was 25%, with rates of 34% and 12% for augmentation and interposition, respectively, and rates of 44%, 23%, and 15% for xenografts, allografts, and synthetic grafts, respectively. CONCLUSIONS We report improvements in clinical and functional outcomes, with similar results for augmentation and interposition techniques, whereas xenografts showed less improvement than synthetic grafts and allografts in PROs and ADLs. Retear rates may be lower with the interposition technique or in patients with synthetic grafts or allografts. LEVEL OF EVIDENCE Level IV, systematic review of Level II through IV studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of Rotator Cuff Repairs Revised to Shoulder Arthroplasty

Background: Successful repair of a torn rotator cuff may prevent progression to rotator cuff arthropathy. However,previous studies have shown a substantial rate of failure after rotator cuff repair and characteristics of surgicallyrepaired rotator cuffs that go on to shoulder arthroplasty have not been fully elucidated. The purpose of this study wasto determine the patient cha...

متن کامل

Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

 Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...

متن کامل

Outcomes After Open Revision Repair of Massive Rotator Cuff Tears With Biologic Patch Augmentation.

PURPOSE To assess minimum 2-year clinical outcomes after open revision biologic patch augmentation in patients with massive rotator cuff retears who had deficient rotator cuff tendons with healthy rotator cuff muscles. METHODS Patients with massive posterosuperior rotator cuff retears who underwent open revision rotator cuff repair with patch augmentation were identified from a surgical regis...

متن کامل

Clinical outcomes in patients undergoing revision rotator cuff repair with extracellular matrix augmentation.

Outcomes following revision surgery for failed rotator cuff repairs are far less predictable than and are associated with decreased patient satisfaction compared with primary repairs. Extracellular matrix augmentation (ECM) may improve the biologic potential for healing during revision repair. The authors examined clinical outcomes and healing rates based on postoperative imaging of patients wh...

متن کامل

All-arthroscopic patch augmentation of a massive rotator cuff tear: surgical technique.

Surgical management of massive rotator cuff tears remains challenging, with failure rates ranging from 20% to 90%. Multiple different arthroscopic and open techniques have been described, but there is no current gold standard. Failure after rotator cuff repair is typically multifactorial; however, failure of tendon-footprint healing is often implicated. Patch augmentation has been described as ...

متن کامل

Biologic and Synthetic Grafts in the Reconstruction of Large to Massive Rotator Cuff Tears.

Rotator cuff injuries are common in both young and elderly patients. Despite improvements in instrumentation and surgical techniques, the failure rates following tendon reconstruction remain unacceptably high. To improve outcomes, graft patches have been developed to provide mechanical strength and to furnish a scaffold for biologic growth across the delicate tendon-bone junction. Although no p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 32 8  شماره 

صفحات  -