Measuring lung liquid volume and secretion using radioiodinated serum albumin and blue dextran

نویسندگان

  • S Cassin
  • A M Perks
چکیده

Cassin, S., and A. M. Perks. Estimation of lung liquid production in fetal sheep with blue dye dextran and radioiodinated serum albumin. J Appl Physiol 92: 1531–1538, 2002; 10.1152/japplphysiol.00777.2001.—Lung liquid production and reabsorption rates and lung volumes were measured in 99 fetal sheep (119–148 days of gestation) by indicatordilution methods with the simultaneous use of blue dye dextran (BDD) and radioiodinated serum albumin (RISA). There were no significant differences between rates of lung liquid production or reabsorption by the two methods (n 71 pairs; paired t-test; Wilcoxon test; ANOVA); this was equally true for rates in milliliters per hour or milliliters per kilogram body weight per hour and was independent of age. Volumes measured by both methods showed a close linear relationship (r 0.97; for slope P 0.0001; n 99), whether expressed as milliliters or milliliters per kilogram body weight. Either method could give the higher volume. Values differed by only 4%, independent of age or parameter (ml or ml/kg body wt; volumes regressed to original volume, or as measured in untreated control hours). However, this small difference was significant by paired t-test or Wilcoxon test when all data were combined irrespective of age; it was not significant after allowance for gestational age (two-way ANOVA). Both indicators showed the same increase in lung volume toward birth and the same fall when related to body weight (slopes significant P 0.0003–0.0004; r 0.93). Two-way ANOVA showed that the declines were significant (P 0.003). The data suggest that 1) there was no significant difference in production or reabsorption rates measured by BDD or RISA, 2) differences in volumes measured by the two indicators were only significant if gestational age was ignored and were too small to have physiological importance, and 3) although BDD and RISA each may have methodological weaknesses, for purposes of measuring lung liquid volumes both are sufficiently accurate and reproducible to obtain meaningful physiological results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of lung liquid production in fetal sheep with blue dye dextran and radioiodinated serum albumin.

Lung liquid production and reabsorption rates and lung volumes were measured in 99 fetal sheep (119-148 days of gestation) by indicator-dilution methods with the simultaneous use of blue dye dextran (BDD) and radioiodinated serum albumin (RISA). There were no significant differences between rates of lung liquid production or reabsorption by the two methods (n = 71 pairs; paired t-test; Wilcoxon...

متن کامل

Errors in estimating lung liquid volume in fetal lambs when using radiolabeled serum albumin and blue dextran.

Fetal lung liquid volume is usually determined by using radio-iodinated serum albumin (RISA) or blue dextran (BD) as volume tracers. We tested the reliability of both tracers at 124 (G124) and 142 days of gestation (G142; term = G147) when the labels were employed simultaneously. We measured the proportion of label bound reversibly to the lung, or apparently lost from the lung compartment, by w...

متن کامل

The origin and consequences of concentration dependence in gel chromatography.

Concentration dependence of elution volume was determined for Blue Dextran 2000, Dextran 500, Dextran sulphate 500 and bovine serum albumin on columns of Sephadex G-100 equilibrated with sodium phosphate buffer, I 0.1, pH6.8. From the results for Dextran 500, it was shown that a linear relation exists between elution volume and the corresponding osmotic pressure calculated for the same concentr...

متن کامل

The estimation of red cell volume with 51Cr-labelled erythrocytes and plasma volume with radioiodinated human serum albumin.

The validity of a simplified procedure for the direct estimation of both red cell and plasma volume, using (51)Cr-labelled erythrocytes and radioiodinated human serum albumin, has been examined. It is suggested that the procedure, involving three venepunctures only, will yield accurate measurements of both compartments.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003