Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries

نویسندگان

  • Mehrdad Abdinian
  • Rahman Nazeri
  • Marzieh Ghaiour
چکیده

Objectives When a patient has cone beam computed tomography (CBCT) images based on the treatment plan, it is possible to use these images for evaluation of caries, and there is no need for new radiographs, according to the "as low as reasonably achievable" (ALARA) principle. The aim of this study was to determine the effect of filtration and thickness of CBCT cross-sections on detection of proximal caries. Materials and Methods In this in-vitro study, 100 teeth were placed in the dental sockets of a dry skull, and were fixed in normal proximal contacts. CBCT images were taken and were evaluated by two observers on the panoramic view at 1-, 3- and 5-mm-thick cross-sections, with the use of filtrations 0, 1 and 2. Afterwards, the samples were sectioned and underwent a histological evaluation. McNemar's test was used to compare the findings on CBCT images and histological evaluation. Receiver operating characteristic (ROC) curves and logistic regression were used to evaluate the diagnostic accuracy of different cross-sections. Results The maximum AZ-value was achieved at 3-mm thickness/filtration 2. However, the differences between 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1 were not significant (P=0.728 and 0.868, respectively). The minimum AZ-value was achieved at 5-mm thickness/filtration 0. Conclusions Although CBCT is not sufficiently effective in detecting caries, the best cross-sections for detection of proximal caries were achieved at 3-mm thickness/filtration 2, 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Evaluation of neurovascular anatomical variations in maxillary anterior region in cone beam computed tomography images

Introduction: Incisive foramen in the maxilla is the oral terminus of the nasopalatine canal. This region is important in implantology, Therefore, the aim of this study was to investigate the  neurovascular anatomical variations in the maxillary anterior region, observed on cone beam computed tomography (CBCT) images. Materials &Methods: In this cross-sectional study, maxillary CBCT ima...

متن کامل

Incidental dentomaxillofacial findings on cone beam computed tomography images of Iranian population

BACKGROUND AND AIM: The present study aimed to assess the nature and prevalence of incidental findings in cone beam computed tomography (CBCT) images of oral and maxillofacial patients. METHODS: In this cross-sectional study, 773 CBCT samples were retrieved from archives of a private oral and maxillofacial radiology center. Any findings that were not related to the reason of CBCT request was re...

متن کامل

Comparison of Cone Beam Computerized Tomography and Phosphor Storage Plate in Detecting Artificial Buccal Recurrent Caries

Introduction Recurrent or secondary caries develops at the margin of restorations and causes restorative failure. We conducted this study to compare the performance of Phosphor Storage Plate (PSP) and Cone Beam Computed Tomography (CBCT) scan in detecting buccal recurrent caries under amalgam and composite resin restorations. Materials and Methods Class V cavities were prepared on the buccal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017