Non-Invasive Detection of Protein Content in Several Types of Plant Feed Materials Using a Hybrid Near Infrared Spectroscopy Model
نویسندگان
چکیده
Near-infrared spectroscopy combined with chemometrics was applied to construct a hybrid model for the non-invasive detection of protein content in different types of plant feed materials. In total, 829 samples of plant feed materials, which included corn distillers' dried grains with solubles (DDGS), corn germ meal, corn gluten meal, distillers' dried grains (DDG) and rapeseed meal, were collected from markets in China. Based on the different preprocessed spectral data, specific models for each type of plant feed material and a hybrid model for all the materials were built. Performances of specific model and hybrid model constructed with full spectrum (full spectrum model) and selected wavenumbers with VIP (variable importance in the projection) scores value bigger than 1.00 (VIP scores model) were also compared. The best spectral preprocessing method for this study was found to be the standard normal variate transformation combined with the first derivative. For both full spectrum and VIP scores model, the prediction performance of the hybrid model was slightly worse than those of the specific models but was nevertheless satisfactory. Moreover, the VIP scores model obtained generally better performances than corresponding full spectrum model. Wavenumbers around 4500 cm-1, 4664 cm-1 and 4836 cm-1 were found to be the key wavenumbers in modeling protein content in these plant feed materials. The values for the root mean square error of prediction (RMSEP) and the relative prediction deviation (RPD) obtained with the VIP scores hybrid model were 1.05% and 2.53 for corn DDGS, 0.98% and 4.17 for corn germ meal, 0.75% and 6.99 for corn gluten meal, 1.54% and 4.59 for DDG, and 0.90% and 3.33 for rapeseed meal, respectively. The results of this study demonstrate that the protein content in several types of plant feed materials can be determined using a hybrid near-infrared spectroscopy model. And VIP scores method can be used to improve the general predictability of hybrid model.
منابع مشابه
Design and fabrication of non-invasive blood glucose sensor using pulse width modulation (PWM) technique and analysis of first harmonic amplitude of near infrared spectroscopy
This article has no abstract.
متن کاملDetermination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares
The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...
متن کاملDevelopment of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection
The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...
متن کاملDetermining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings
Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...
متن کاملCorrelation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass
Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...
متن کامل