A Near-Field Goniospectroradiometer for LED Measurements
نویسندگان
چکیده
Designing micro-optics for light-emitting diodes must take into account the near-field radiance and relative spectral power distributions of the emitting LED die surfaces. We present the design and application of a near-field goniospectroradiometer for this purpose.
منابع مشابه
Realization of the NIST Total Spectral Radiant Flux Scale
The total spectral radiant flux scale has been realized at National Institute of Standards and Technology using a goniospectroradiometer for the 360 nm to 800 nm region. The construction of the goniospectroradiometer and results of the scale realization as well as the uncertainty budget are presented. Introduction. There are increasing needs for total spectral radiant flux standards, which are ...
متن کاملA Strong Ground Motion Catalogue of Selected Records for Shallow Crustal, Near Field Earthquakes in Iran
Understanding strong ground motions in the near-fault areas is important for seismic risk assessment in densely populated areas. In the past, lack of information on strong ground motion for large and moderate earthquakes led to the use of mainly far field large and moderate earthquake records in equations for calculation of the strong ground motion parameters. In this article, we collected and ...
متن کاملEvaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...
متن کاملDosimetric accuracy of the Acuros XB and Anisotropic analytical algorithm near interface of the different density media for the small fields of a 6- MV flattening-filter-free beam
Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a 6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...
متن کاملA study of magnetic drift motion of particles around the equatorial plasmapause by using the cluster observation
On August 7, 2003 the Cluster spacecraft moved through the dayside magnetosphere. The energetic particle spectrometer on board Cluster provided measurements of an extensive range of energy. Besides, satellite measurements of geomagnetic field showed a gradient magnetic field. It is known that an inhomogeneity of the magnetic field leads to a drift of charged particles. In this paper, the drift ...
متن کامل