A Nitrite Biosensor Based on Co-immobilization of Nitrite Reductase and Viologen-modified Chitosan on a Glassy Carbon Electrode

نویسندگان

  • De Quan
  • Woonsup Shin
چکیده

An electrochemical nitrite biosensor based on co-immobilization of copper-containing nitrite reductase (Cu-NiR, from Rhodopseudomonas sphaeroides forma sp. denitrificans) and viologen-modified chitosan (CHIT-V) on a glassy carbon electrode (GCE) is presented. Electron transfer (ET) between a conventional GCE and immobilized Cu-NiR was mediated by the co-immobilized CHIT-V. Redox-active viologen was covalently linked to a chitosan backbone, and the thus produced CHIT-V was co-immobilized with Cu-NiR on the GCE surface by drop-coating of hydrophilic polyurethane (HPU). The electrode responded to nitrite with a limit of detection (LOD) of 40 nM (S/N = 3). The sensitivity, linear response range, and response time (t(90%)) were 14.9 nA/μM, 0.04-11 μM (r(2) = 0.999) and 15 s, respectively. The corresponding Lineweaver-Burk plot showed that the apparent Michaelis-Menten constant (K(M) (app)) was 65 μM. Storage stability of the biosensor (retaining 80% of initial activity) was 65 days under ambient air and room temperature storage conditions. Reproducibility of the sensor showed a relative standard deviation (RSD) of 2.8% (n = 5) for detection of 1 μM of nitrite. An interference study showed that anions commonly found in water samples such as chlorate, chloride, sulfate and sulfite did not interfere with the nitrite detection. However, nitrate interfered with a relative sensitivity of 64% and this interference effect was due to the intrinsic character of the NiR employed in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modified Glass Carbon Electrode (GCE) Electropolymerized Polypyrrole Nanofibers with Hemoglobin (Hb) Film as a Unique Biosensor for Nitrite Determination

Abstract: In this study, we were investigated behavior the electrochemical reductionof nitrite at a hemoglobin (Hb) immobilized on glass carbon electrode (GCE) containingpolypyrol nanofiber (ppy) films. Polypyrrole (PPy) nanofibers have been constructed onGCE applying electrochemical technique, and can to deposit diverse polymers onminiaturized electrodes with this commo...

متن کامل

Direct Electrochemistry of Hemoglobin on Graphene Nanosheet-based Modified Electrode and Its Electrocatalysis to Nitrite

A novel amperometric nitrite (NO2 − ) sensor was developed based on immobilization of hemoglobin (Hb) on a graphene nanosheet modified electrode by chitosan-N, N-Dimethylformamide (CS-DMF) hydrogel. The surface morphologies of the modified electrode were characterized by SEM, and direct electrochemistry of Hb on the graphene nanosheet-based electrode were investigated by cyclic voltammetry. The...

متن کامل

Electrochemical determination of nitrite and iodate based on Pt nanoparticles self-assembled on a chitosan modified glassy carbon electrode.

A promising electrochemical sensor was fabricated by the self-assembling of Pt nanoparticles (nano-Pts) on a chitosan (CS) modified glassy carbon electrode (GCE). A field-emission scanning electron microscope (FE-SEM), transmission electron microscopy (TEM) and electrochemical techniques were used for characterization of these composites. It has been found that nano-Pts are inserted into the CS...

متن کامل

Design and Fabrication of Biosensor Based on Immobilized AchE on Modified Electrode by Graphene-multiwall Carbon Nanotubs/Beta Cyclodexterin-chitosan

Organophosphorus (OP) forms an important class of toxic compounds. They inhibit acetyl cholinesterase (AChE, EC 3.1.1.7) that results in respiratory and myocardial malfunctions. Pesticides could be accumulated in vegetables and fruits, so detection of them is very important. The goals of this study are decreasing detection time and detection limit of methyl parathion bioprobe. In this research ...

متن کامل

Application of carbon ceramic modified electrode with prussian blue for electrocatalytic oxidation of nitrite ion

A novel chemically modified electrode containing Prussian blue complex was achieved on the surface of glass carbon electrode by sol-gel technique. The electrochemical behavior of modified electrode was characterized by cyclic voltammetry in detail. The film electrode obtained was very stable and exhibited electrocatalytic response for oxidation of nitrite. Results showed at bare GC electrode, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010