Cell Culture Optimization Using an Agilent Bio-Monolith Protein A Column and LC/MS Authors

نویسندگان

  • Emmie Dumont
  • Isabel Vandenheede
  • Phu Duong
  • Maureen Joseph
چکیده

This application note describes how the Agilent Bio-Monolith Protein A column was applied to the optimization of Chinese hamster ovary cell-culture conditions to produce a recombinant monoclonal antibody with desired structural characteristics, focusing on glycosylation. The workflow demonstrates the versatility and wide applicability of the column in biopharmaceutical and biosimilar development.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi - Preparative Purifi cation and Characterization of Lysozyme Modifi ed with Poly Ethylene Glycol ( PEG ) The Agilent 1260

This Application Note used hen egg white lysozyme as a model protein for purifi cation and biophysical characterization of PEGylated proteins. PEGylation to the N-terminus of lysozyme in a site-specifi c manner was achieved using PEG-propionaldehyde derivatives with a molecular weight of Mw 20,000. A semi-preparative RP-HPLC method for the purifi cation of PEGylated lysozyme was developed using...

متن کامل

Analysis of Potential Genotoxic Arylamine and Aminopyridine Impurities in Active Pharmaceutical Ingredients Agilent 1290 Infinity LC system and Agilent 6460A Triple Quadrupole MS system for method development and fast analysis

This Application Note illustrates the possibilities of the Agilent 1290 Infinity LC system and the Agilent 6460A Triple Quadrupole Mass Spectrometer for quantitative analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs). A generic approach was used to determine arylamine and aminopyridine PGIs in selected APIs. The influence of column length and mobile ph...

متن کامل

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column Authors

An Agilent ZORBAX sub-2 μm Rapid Resolution High Definition (RRHD) 300SB-C8 reversed-phase column was used under optimized chromatographic conditions for delivering highly resolved ultra fast separations of reduced and alkylated monoclonal antibodies. The StableBond C8 phase and RRHD column technology, in combination with robust gradient elution conditions enabled efficient, fast, and effective...

متن کامل

Characterization of monoclonal antibodies on the Agilent 1260 Infinity Bio-inert Quaternary LC by Size Exclusion Chromatography using the Agilent BioSEC columns

The Agilent 1260 Bio-inert Quaternary LC System and Agilent BioSEC columns were used to investigate the purity and stability of two monoclonal antibodies (mAb): AntiFLAG and BL05. The high sensitivity of the Agilent 1260 Infinity Diode Array Detector was used to characterize these antibodies at low concentrations. The bio-inert LC system in combination with BioSEC columns resulted in the develo...

متن کامل

Fast Monitoring of Bacteriophage Production During Fermentation Using the Agilent Bio-Monolith HPLC Column

Bacteriophages, viruses that infect bacteria, were discovered at the beginning of the twentieth century. Today, phages are being used as antibacterial agents, in phage display screening, in the development of phage delivery vaccines, as targeted gene therapy delivery systems, and for specific bacteria typing. In order to use phages in these applications, they are commonly purified by liquid chr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014