MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry.

نویسندگان

  • Luiz C Oliveira
  • Eduardo G Yukihara
  • Oswaldo Baffa
چکیده

The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emission spectrum of this new material and carried out a preliminary investigation on the OSL signal stability. MgO:Li,Ce,Sm has a main TL peak at ~180 °C (at a heating rate of 5 °C/s) associated with Ce(3+) and Sm(3+) emission. The results indicate that the infrared (870 nm) stimulated OSL from MgO:Li,Ce,Sm has suitable properties for dosimetry, including high sensitivity to ionizing radiation (20 times that of Al2O3:C, under the measurement conditions) and wide dynamic range (7 μGy-30 Gy). The OSL associated with Ce(3+) emission is correlated with a dominant, practically isolated peak at 180 °C. Fading of ~15% was observed in the first hour, probably due to shallow traps, followed by subsequent fading of 6-7% over the next 35 days. These properties, together with the characteristically fast luminescence from Ce(3+), make this material also a strong candidate for 2D OSL dose mapping.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی خصوصیات پایه ای دزیمتریک بلور کلسیم سولفید آلاییده شده با عناصر خاکی کمیاب به عنوان حساسه ی دزیمتر OSL

Background and Aim: Today, OSL (Optically Stimulated Luminescence) dosimetry system based on optical stimulation, includes systems that can meet many requirements for radiation protection in the field of medicine and space.  The Calcium Sulfide (CaS) is one of the earth's alkaline sulfide materials which can be used as a detector in this system. In this research, some of the dosimetry propertie...

متن کامل

ساخت و بهینه‌سازی قرص‌های کامپوزیتی نانوفسفر استرانسیوم سولفید آلاییده با سریم و ساماریوم (SrS:Ce, Sm)، به عنوان آشکارساز تشعشع فضایی

In this study, the SrS nanopowder co-activated by Ce3+ and Sm3+ (SrS:Ce,Sm) was synthesized by the co-precipitation method. The transparent pellets were fabricated by mixing the SrS:Ce,Sm nanopowder and bisphenol-A epoxy resin as a crystal of the optically stimulated luminescence (OSL) dosimeter. The crystalline phase verification and also, the morphology of the synthesized nanopowder were inve...

متن کامل

Lexsyg Smart — a Luminescence Detection System for Dosimetry, Material Research and Dating Application

Following the luminescence system lexsyg research, which was designed for research, the luminescence reader lexsyg smart for the application of luminescence detection was developed by Freiberg Instruments. It is suited for routine measurements of luminescence (thermoluminescence, photoluminescence, photon-stimulated, optically stimulated and infrared stimulated luminescence) for a wide range of...

متن کامل

Optically stimulated luminescence in synthetic quartz

Optically stiniulated luminescence (OSL). has been studied in synthetic quartz crystals. which had previously been exposed to Jtor X-irradiations. The main emission hands appeared at 380 and -~440 nm. The excitation spectra of these emission bands were now measured and showed both a maximum at 330nm. This maximum coincides with an excitation maximum of the phototransferred thermoluminescence (P...

متن کامل

Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.

A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Scientific reports

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016