Continuous-flow analysis of ammonia in perchloric acid supernate of blood or plasma using an ammonia-selective electrode.

نویسندگان

  • G C Moses
  • R J Thibert
  • T F Draisey
چکیده

A simple automated method for the estimation of ammonia in perchloric acid supernate of blood or plasma using an ion-selective electrode (Orion Ammonia-selective electrode, Model 95-10) is described. The reliability of the proposed method has been checked against an ion-exchange resin procedure, which has been chosen as a standard procedure. Regression equation and correlation coefficient for the proposed method are y = 0.7 X + 10 and 0.945, respectively, as compared with the chosen standard method. Within-run and between-run precision are 2.1% and 3.5% respectively. The average percent recovery is 97.5% and a tentative range is 13-73 microgram/dl (9-52 micronmol/l) ammonia nitrogen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid determination of ammonia in a perchloric acid supernate from blood, by use of an ammonia-specific electrode.

A simple,rapidmethod was developed foraccurate determinationof ammonia inwhole blood.Blood proteins were precipitated with perchioric acid (8 g/dl) and the free ammonia liberatedinthe supernateon alkalinization was measured directlywithan ammonia-specific electrode after adjusting the sample temperature to 25 #{176}C. Some variablesaffectingprecision,accuracy, and electrodeperformance were stud...

متن کامل

Micromethod for determining plasma ammonia nitrogen with use of an ion-selective electrode.

A micromethod for measuring the ammonia nitrogen content of plasma by use of an ion-selective electrode is evaluated and described. The effect of storing plasma for 24, 48, and 72 h at -70 degrees C was evaluated. Values for newborns and fasting adults were 880 micrograms/L (SD, 210 micrograms/L) and 620 micrograms/L (SD, 170 micrograms/L), respectively.

متن کامل

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Determination of ammonia and urea in urine and of urea in blood by use of an ammonia-selective electrode.

I propose a single, quick method for measuring ammonia in urine and urea in plasma and urine. An ammonia-selective electrodie is used, set up on a microcell, which allows use of small sample volumes. Ammonia is measured directly after partial conversion of ammonium ions to NH3. Urea is measured after its hydrolysis by urease. With urine, the two procedures can be carried out successively in the...

متن کامل

Continuous-flow Enzymatic Determination of Creatinine with Improved On-line Removal of Endogenous Ammonia

A new continuous-flow automated enzymatic method suitable for the direct determination of creatinine in physiological samples is described. The proposed system utilizes an on-line gas predialysis unit in conjunction with a flow-through enzyme reactor coil and a potentiometric ammonia detector. The enzyme reactor contains immobilized creatinine iminohydrolase (EC 3.5.4.21) which converts creatin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 31 12  شماره 

صفحات  -

تاریخ انتشار 1978