Thrombolysis of a modified Blalock-Taussig shunt with recombinant tissue plasminogen activator in a newborn infant with pulmonary atresia and ventricular septal defect.

نویسندگان

  • M Ries
  • H Singer
  • M Hofbeck
چکیده

A 10 day old infant with pulmonary atresia, ventricular septal defect, and collateral pulmonary blood supply through a left sided ductus arteriosus developed complete shunt thrombosis four days after the creation of a modified Blalock-Taussig shunt. Recombinant tissue plasminogen activator was given locally into the proximal end of the shunt as two bolus injections of 0.1 mg/kg and two bolus injections of 0.2 mg/kg over 10 minutes, followed by a continuous infusion of 1.4 mg/kg/day for 16 hours and 0.7 mg/kg/day for 18 hours with systemic low dose heparin 5 IU/kg/h. This resulted in complete clot dissolution and reperfusion without haemorrhagic complications and without laboratory signs of systemic fibrinolytic activation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...

متن کامل

Recanalisation of an occluded modified Blalock-Taussig shunt by balloon dilatation.

A four year old boy with pulmonary atresia and ventricular septal defect had an acute cyanotic episode three years after undergoing a right-sided, 6 mm diameter, modified Blalock-Taussig shunt. On admission no continuous murmur could be heard from the shunt and the typical high velocity, continuous flow profile of the shunt could not be identified by Doppler echocardiography. At catheterisation...

متن کامل

Balloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence of proximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months l...

متن کامل

Ebstein’s Anomaly: An Impressive Cardiothoracic Ratio

Cardiothoracic ratio upper to 0.60 is a factor of poor prognostic in patients with Ebstein’s anomaly and the prognostic is worse if is associated with others congenital heart disease. We present 4-months black boy with Ebstein’s anomaly associated with atrial septal defect, pulmonary valve atresia and patent ductus arteriosus wherein the cardiothoracic ratio nearly 1.0. The patient died five ho...

متن کامل

Ductal stenting for acute thrombosis of modified Blalock-Taussig shunts.

transannular patch was placed and stent flow was interrupted with a clip. A 1500-g neonate diagnosed with pulmonary atresia with ventricular septal defect, right aortic arch, ductus left and left superior vena cava, was administered prostaglandin to 2 months and underwent a right MBT shunt. Prostaglandin perfusion was restarted at 24 h as saturation was <65%. Echocardiography detected no flow i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 1994